Core Purpose Statement
This guide covers YN/Y series stainless steel (SS) pressure gauges, including models like YN-100BF-ZQ, Y-60B-F, and YN-153B-F. These gauges are specifically designed to match equipment such as stainless steel pressure vessels (e.g., 304/316L storage tanks), chemical pumps (IH series), food-grade pipelines, and marine hydraulic systems. Targeted at petrochemical plants, food & beverage manufacturers, marine engineering firms, and pharmaceutical enterprises, they address core needs for corrosion resistance, pressure measurement accuracy, and stable operation in harsh environments (corrosive media, vibration, high humidity). Compliant with EN 837-1 and GB/T 1226-2010 standards, they eliminate risks of gauge failure caused by corrosive media and vibration, ensuring reliable pressure monitoring for critical industrial processes.
Product Classification & Detailed Specifications
1. 60mm Dial Diameter Stainless Steel Pressure Gauges (Y-60B-F, YN-60B-F)
Optimized for compact installation spaces in corrosive and low-vibration environments, 60mm dial gauges resolve issues of inaccurate measurement and gauge damage in narrow pipelines. Ideal for small-diameter chemical pipelines, mini pressure vessels, and food processing equipment auxiliary systems. Their compact design and stainless steel construction ensure corrosion resistance and easy reading, critical for reliable pressure monitoring in limited-space harsh environments. (79 words)
Product No. | Product Model | Material | Main Wear Reasons | Damage Prevention Notes |
1 | Y-60B-F | 304 stainless steel case & bezel; 316L stainless steel pressure element; tempered glass window; fluororubber sealing ring | 1. Corrosion of pressure element by acidic/alkaline media due to improper selection of wetted parts; 2. Glass window breakage caused by accidental impact in narrow installation spaces | 1. Confirm the compatibility of 316L wetted parts with the measured medium (e.g., avoid strong oxidizing acids like concentrated nitric acid); 2. Install a protective cover around the gauge in high-traffic narrow areas; ensure a minimum 5mm clearance from adjacent components |
2 | YN-60B-F | 304 stainless steel case & bezel; 316L stainless steel pressure element; tempered glass window; silicone oil filling (vibration damping); nitrile rubber sealing ring | 1. Deterioration of silicone oil due to long-term operation at high temperatures (exceeding 60℃), reducing vibration damping effect; 2. Seal ring aging caused by exposure to organic solvents in chemical environments | 1. Ensure operating temperature does not exceed 60℃; replace silicone oil with high-temperature resistant type (≥100℃) if needed; 2. Inspect seal ring quarterly for cracks; replace with fluororubber seals in organic solvent environments |
2. 63mm Dial Diameter Stainless Steel Pressure Gauges (Y-63B-F, YN-63B-F)
Designed for medium-narrow installation spaces requiring higher readability than 60mm models, 63mm dial gauges address issues of difficult reading and vibration-induced measurement errors. Suitable for small-scale petrochemical pipelines, pharmaceutical reaction kettles (laboratory scale), and marine auxiliary equipment. Their enhanced readability and vibration-resistant design (for YN models) ensure accurate pressure monitoring in semi-harsh environments. (76 words)
Product No. | Product Model | Material | Main Wear Reasons | Damage Prevention Notes |
1 | Y-63B-F | 304 stainless steel case & bezel; 316L stainless steel pressure element; reinforced tempered glass window; EPDM rubber sealing ring | 1. Oxidation of stainless steel case surface due to high humidity in marine environments; 2. Pressure element fatigue caused by frequent pressure fluctuations beyond 120% of rated range | 1. Apply anti-corrosion wax to the case surface annually for marine applications; clean salt spray residue with fresh water monthly; 2. Install a pressure relief valve upstream to limit pressure fluctuations within ±10% of rated range |
2 | YN-63B-F | 304 stainless steel case & bezel; 316L stainless steel pressure element; reinforced tempered glass window; glycerin filling (vibration damping); fluororubber sealing ring | 1. Glycerin leakage caused by loose bezel screws due to vibration; 2. Blockage of pressure inlet by viscous media (e.g., food syrup, heavy oil) | 1. Retighten bezel screws quarterly with torque wrench (torque: 2-3N·m); check for glycerin leakage; 2. Install a filter at the pressure inlet for viscous media; clean the filter monthly to ensure unobstructed pressure transmission |
3. 100mm Dial Diameter Stainless Steel Pressure Gauges (Y-100B-F, YN-100B-F, YN-100BF-ZQ)
Engineered for standard industrial applications requiring high readability and corrosion resistance, 100mm dial gauges resolve issues of measurement inaccuracy, vibration damage, and corrosion failure in harsh industrial environments. Suitable for large chemical pipelines, stainless steel pressure vessels (304/316L), and hydraulic systems in petrochemical plants. Their robust construction and vibration damping (YN models) ensure long-term reliable operation in Zone 2 hazardous areas. (78 words)
Product No. | Product Model | Material | Main Wear Reasons | Damage Prevention Notes |
1 | Y-100B-F | 304 stainless steel case & bezel; 316L stainless steel pressure element; safety glass window; EPDM rubber sealing ring | 1. Corrosion of pressure element by chloride ions in seawater or brine environments; 2. Window fogging caused by temperature difference leading to moisture ingress | 1. For chloride-rich environments, upgrade to 316Ti stainless steel pressure element; 2. Insulate the gauge in environments with large temperature differences; check for window fogging monthly and dry the internal cavity if needed |
2 | YN-100B-F | 304 stainless steel case & bezel; 316L stainless steel pressure element; safety glass window; silicone oil filling (vibration damping); fluororubber sealing ring | 1. Silicone oil contamination caused by leakage of measured media into the gauge cavity; 2. Pressure element deformation due to overpressure (exceeding 150% of rated range) | 1. Install a pressure limiter upstream with a set pressure 10% lower than the gauge's overpressure limit; 2. Check the color and transparency of silicone oil quarterly; replace oil and inspect sealing if contamination is found |
3 | YN-100BF-ZQ | 304 stainless steel case & bezel; 316L stainless steel pressure element (zinc-plated); safety glass window; high-viscosity silicone oil filling; double fluororubber sealing rings | 1. Zinc plating peeling on pressure element due to long-term exposure to acidic media; 2. Loosening of pressure connection threads caused by mechanical vibration | 1. Avoid using in strong acidic environments (pH < 4); use acid-resistant coating for the pressure element if necessary; 2. Use thread locking adhesive on pressure connection threads; retighten quarterly with torque wrench (torque: 8-10N·m) |
4. 103mm Dial Diameter Stainless Steel Pressure Gauges (Y-103B-F, YN-103B-F)
Tailored for precision pressure measurement in corrosive and high-vibration industrial environments, 103mm dial gauges address issues of low measurement precision and short service life in harsh conditions. Suitable for pharmaceutical reaction kettles (GMP compliant), high-purity chemical pipelines, and precision hydraulic systems. Their enhanced precision mechanism and corrosion-resistant materials ensure accurate pressure monitoring for high-quality control processes. (77 words)
Product No. | Product Model | Material | Main Wear Reasons | Damage Prevention Notes |
1 | Y-103B-F | 316 stainless steel case & bezel; 316L stainless steel pressure element; borosilicate glass window; PTFE sealing ring | 1. Abrasion of precision gear mechanism by dust ingress in cleanroom environments; 2. Corrosion of internal components by aggressive pharmaceutical media (e.g., APIs) | 1. Install a dust cover on the gauge in cleanrooms; clean the case surface with alcohol daily; 2. Select PTFE-lined pressure elements for aggressive pharmaceutical media; validate media compatibility before use |
2 | YN-103B-F | 316 stainless steel case & bezel; 316L stainless steel pressure element; borosilicate glass window; medical-grade glycerin filling; double PTFE sealing rings | 1. Medical-grade glycerin degradation caused by UV exposure in cleanroom lighting; 2. Pressure element fatigue due to frequent start-stop of precision hydraulic systems | 1. Install a UV-protective cover on the gauge in cleanrooms with UV lighting; 2. Reduce pressure fluctuations during system start-stop by using a buffer tank; check gauge accuracy quarterly with a calibration pump |
5. 150mm Dial Diameter Stainless Steel Pressure Gauges (Y-150B-F, YN-150B-F)
Designed for large-scale industrial equipment requiring high readability and heavy-duty performance, 150mm dial gauges resolve issues of difficult reading and structural damage in high-pressure, high-vibration environments. Suitable for large chemical reactors, marine main pipelines, and oil refinery pressure vessels. Their robust heavy-duty construction and enhanced vibration damping ensure reliable operation in harsh industrial conditions with high visibility. (76 words)
Product No. | Product Model | Material | Main Wear Reasons | Damage Prevention Notes |
1 | Y-150B-F | 304 stainless steel heavy-duty case; 316L stainless steel pressure element (reinforced); safety tempered glass window; fluororubber sealing ring | 1. Case deformation caused by mechanical impact in heavy industrial environments; 2. Pressure element rupture due to sudden overpressure (water hammer effect) | 1. Install a heavy-duty protective guard around the gauge; ensure the guard can withstand impact force ≥50J; 2. Install a water hammer arrester upstream to absorb sudden pressure surges; set the arrester pressure 5% lower than the gauge's rated pressure |
2 | YN-150B-F | 304 stainless steel heavy-duty case; 316L stainless steel pressure element (reinforced); safety tempered glass window; high-viscosity glycerin filling; double fluororubber sealing rings | 1. Glycerin leakage from case seams due to high vibration in marine main engines; 2. Corrosion of pressure connection by sulfur-containing media in oil refineries | 1. Use vibration isolation brackets to mount the gauge; check for glycerin leakage monthly and retighten case bolts; 2. For sulfur-containing environments, use Hastelloy C-276 pressure connections; inspect for corrosion quarterly |
6. 153mm Dial Diameter Stainless Steel Pressure Gauges (Y-153B-F, YN-153B-F)
Optimized for precision high-pressure measurement in corrosive and high-vibration environments, 153mm dial gauges address issues of low precision and poor durability in extreme industrial conditions. Suitable for high-pressure chemical reactors, offshore drilling platform pipelines, and supercritical fluid systems. Their precision-engineered pressure elements and heavy-duty corrosion-resistant construction ensure accurate and reliable pressure monitoring in extreme harsh environments. (78 words)
Product No. | Product Model | Material | Main Wear Reasons | Damage Prevention Notes |
1 | Y-153B-F | 316L stainless steel case & bezel; Hastelloy C-276 pressure element; borosilicate glass window; PTFE sealing ring | 1. Hastelloy pressure element corrosion by strong oxidizing media (e.g., concentrated sulfuric acid); 2. Glass window damage by sandblasting in offshore drilling environments | 1. Validate media compatibility with Hastelloy C-276 before use; avoid using in concentrated oxidizing acid environments without prior testing; 2. Install a sandproof cover on the gauge in offshore drilling areas; replace the cover if damaged |
2 | YN-153B-F | 316L stainless steel case & bezel; Hastelloy C-276 pressure element; borosilicate glass window; high-temperature silicone oil filling (vibration damping); double PTFE sealing rings | 1. High-temperature silicone oil degradation at operating temperatures exceeding 120℃; 2. Pressure element fatigue due to cyclic high-pressure operation (0-100% rated pressure) | 1. Ensure operating temperature does not exceed 120℃; use heat-resistant insulation between the gauge and high-temperature pipelines; 2. Conduct fatigue testing annually; replace the pressure element if the measurement error exceeds ±1.6% of full scale |
Procurement & Technical Reference Standards
1. Procurement Reference Standards
Certification Compliance: Prioritize products certified to EN 837-1 (European standard) and GB/T 1226-2010 (Chinese national standard), with materials meeting ASTM A240 (stainless steel) requirements. For hazardous environments, ensure compliance with ATEX Zone 2 certification.
Parameter Matching: Confirm the gauge's rated pressure range (match 1.5-2 times the measured pressure), accuracy class (≥1.6 for industrial use, ≥1.0 for precision applications), dial diameter (based on installation space and readability needs), and wetted part material (316L/316Ti/Hastelloy) matching the measured medium.
Environmental Adaptability: Select filling media (silicone oil/glycerin) based on vibration level (high viscosity for strong vibration) and temperature range (-20℃ to 120℃ for standard filling, -40℃ to 150℃ for high-temperature filling). Choose sealing rings (EPDM/PTFE/fluororubber) based on chemical compatibility with the environment.
Quality & Reliability: Verify the gauge's overpressure capacity (≥150% of rated pressure), service life (≥50,000 pressure cycles), and leak-tightness (tested at 1.25 times rated pressure for 30 minutes). Check the manufacturer's ISO 9001 quality management system certification.
2. Technical Problem-Solving Reference Standards
Inaccurate Measurement: Check for calibration drift, pressure element damage, or filling media contamination. Recalibrate the gauge using a dead-weight tester or precision calibration pump (calibration interval: 6-12 months). Replace the pressure element or filling media if calibration fails.
Gauge Leakage: Inspect sealing rings, bezel screws, and pressure connections for looseness or damage. Replace worn sealing rings with compatible materials, retighten bezel screws to specified torque, and use thread sealant for pressure connections. Conduct a leak test with nitrogen after repair.
Vibration-Induced Damage: Verify if the filling media is suitable for the vibration level. Replace standard filling with high-viscosity silicone oil or glycerin. Install vibration isolation brackets or dampers between the gauge and the pipeline. Ensure the gauge is mounted perpendicular to the vibration direction.
Corrosion Issues: Check if the wetted parts and case material are compatible with the measured medium and environment. Upgrade to corrosion-resistant materials (e.g., 316Ti, Hastelloy) if needed. Apply anti-corrosion coatings to the case surface and install a chemical-resistant protective cover.
Procurement Invitation
YN/Y series stainless steel pressure gauges are engineered to deliver reliable, accurate pressure measurement in harsh industrial environments, combining corrosion resistance, vibration damping, and high readability. Whether you need gauges for petrochemical processes, food & beverage production, marine engineering, or pharmaceutical manufacturing, we offer a comprehensive range of models to meet your specific media compatibility, pressure range, and installation requirements. Contact our professional sales team today to obtain detailed product data sheets, material compatibility charts, and competitive pricing. Our technical experts will provide tailored recommendations based on your operating environment and measurement needs, supporting your critical process monitoring and quality control objectives.
contact us :
Emeil: [email protected] whatsapp: +86 15275658619
Should you have any purchase intentions, please contact us – we will offer you our most favorable price.