11 Mar 2026

Explosion-Proof & Weatherproof Security Solutions Supply: ST40-IP, YHV65-EP0 & EX286 Series

Product Introduction: High-Quality OEM-Compatible Spares for Hazardous & Industrial Environments

This document focuses on the production and supply of premium, OEM-compatible spare parts engineered specifically for explosion-proof surveillance, weatherproof alarm systems, industrial communication, subsea monitoring, and safe area security. Our comprehensive product portfolio covers eight core categories, each designed to meet the rigorous demands of harsh, high-risk environments, with all models fully compliant with global safety certifications and standards. The key products include: explosion-proof monitors & displays (YHJ-151 explosion-proof monitor, YHJ-171 explosion-proof display); explosion-proof & weatherproof camera stations (Camera Station EX286, Camera Station EX286W PTZ JB, MCS3W Weatherproof pan, tilt, zoom camera station, ST40-IP Explosion Protected IP PTZ Camera Station with Illumination, SC40-H Analogue-IP Hybrid PTZ Camera Station, XC40-H Explosion Protected Analogue-IP Hybrid PTZ Camera Station, XT40 Explosion Protected Analogue PTZ Camera Station, EX291 SubSea Fixed Camera Station, Camera Station S9 HD IP, XF26 Explosion Protected Analogue Fixed Camera Station); explosion-proof & weatherproof cameras (YHV65-EP0, YHV40-HP0, YHV50-EP0 stainless steel dome cameras, YHT500 explosion-proof infrared camera, YHT100N endoscopic explosion-proof camera, SF40-Ti Safe Area Thermal Imaging Fixed Camera Stations, SF40-H/SF40/SAF40 Safe Area Analogue Fixed Camera Stations); explosion-proof & weatherproof alarm & beacon devices (Explosionproof Strobe Light dSLB20 for Zone 1,2,21,22, Explosionproof Strobe Light BDK22 for Zone 22, LD15 High Output LED Beacons Exd Weatherproof, XB13 10 Joule Xenon Beacons, XB4 21 Joule Xenon Exd(e) Weatherproof, Weatherproof Obstruction Light SkyLine Alpha 2/4, DB3B Up to 125dB Ex d(e) Weatherproof Hooter, Weatherproof Signalling Hooter HGK/HGW11, Explosionproof Signalling Hooter dGH21 for Zone 1+21 UL approval, Explosionproof Sounder dEV20 for Zone 1+2,21+22, DB12/XB13 Heavy Duty Industrial & Marine Device, DB3/XB11 Exd(e) Heavy Duty Industrial & Marine Device, DB10 Up to 15 Watts Exde Weatherproof Loudspeaker, Explosionproof Loudspeaker for Zone 1+2 INMETRO approval); industrial mounting & protective components (YHZ-B3/YHZ-B4/YHZ-B5 mounting brackets, MD6004C fully sealed camera protective cover, YHQC-5X series camera movement); industrial control & transmission equipment (INKC500 control keyboard, KJ2028K explosion-proof controller, EACU-202 Explosion-proof transmission control unit); explosion-proof lighting (Explosionproof LED Lamp Expertline); and industrial communication devices (YHIP-800B digital wall-mounted telephone station, YHIP-700 digital explosion-proof industrial telephone station, FHF11883020 Telephone Relay TAR 21). All parts adhere to ATEX, IEC Ex, UL, GOST, and INMETRO standards, with IP65/IP66/IP68 protection ratings, compliance with Zone 1/2/21/22 hazardous area classifications, and ISO 9001:2016 quality certification. Our core goal is to provide durable, high-performance spares that resolve common system failures, minimize unplanned downtime, and maintain the safety and operational integrity of critical systems—essential for subsea operations, oil and gas refineries, chemical plants, marine vessels, mining sites, industrial complexes, and cold-storage facilities where system malfunctions can lead to safety risks, property damage, or costly operational disruptions.

Core Purpose & Target User Segmentation & Needs

The core purpose of our product lineup is to supply reliable, compatible, and certified spare parts that enable seamless maintenance, repair, and replacement of critical security, alarm, communication, and control systems in harsh and hazardous environments. These parts are engineered to work in tandem—ensuring 24/7 surveillance coverage (including subsea and endoscopic monitoring), timely emergency alerts, clear industrial communication, and stable signal transmission—while meeting the strict safety regulations of high-risk industries. Below is a breakdown of target users and their specific needs, along with the pain points our products solve:

 Subsea Operations Technicians: Need subsea-rated surveillance equipment (EX291 SubSea Fixed Camera Station) that withstands high water pressure (up to 1000 meters) and corrosion, along with weatherproof obstruction lights (SkyLine Alpha 2/4) for subsea platform safety. Pain points: Scarcity of subsea-compatible camera stations, corrosion-induced failure in saltwater environments, non-certified parts risking subsea operational safety.

 Oil & Gas Safety Engineers: Require explosion-proof surveillance (ST40-IP, XT40 PTZ cameras, YHV65-EP0 dome cameras) and alarm devices (dSLB20 strobe light, dGH21 hooter UL approved) compliant with Zone 1/2/21/22 standards to prevent ignition of flammable gases. Pain points: Incompatible spares causing system downtime, uncertified parts leading to regulatory fines, poor visibility in low-light or harsh weather conditions.

 Marine Operations Managers: Need heavy-duty, saltwater-resistant components (XB13 10 Joule Xenon Beacons, DB12/XB13 devices, SF40-H cameras in 316L stainless steel) that withstand salt spray, high humidity, and extreme marine conditions. Pain points: Corrosion-induced component failure, difficulty finding marine-grade explosion-proof spares, unreliable communication in harsh marine environments.

 Industrial Maintenance Teams: Need versatile, easy-to-install spares (YHZ-B3/B4/B5 mounting brackets, MD6004C camera protective covers, YHQC-5X camera movement) that integrate with existing systems and withstand high temperatures, dust, and chemical exposure. Pain points: Time-consuming installation of incompatible parts, frequent maintenance due to poor structural durability, lack of technical support for specialized components like endoscopic cameras (YHT100N).

 Industrial Communication Specialists: Require explosion-proof telephone stations (YHIP-800B, YHIP-700) and telephone relays (FHF11883020 TAR 21) that enable clear, secure communication in hazardous areas. Pain points: Poor audio quality in high-noise industrial environments, communication failures due to dust/moisture ingress, non-compliant communication devices risking safety violations.

 Mining & Hazardous Area Technicians: Need explosion-proof controllers (KJ2028K), control keyboards (INKC500), and transmission units (EACU-202) that ensure stable system control and signal transmission in Zone 1+2/21+22 areas. Pain points: Signal loss in harsh mining conditions, controller failure due to dust/vibration, difficulty sourcing INMETRO/GOST approved components.

Our products directly address these pain points by offering 100% OEM compatibility, global safety certification (UL, GOST, INMETRO), rugged construction tailored to specific environments, and easy installation—ensuring minimal downtime, regulatory compliance, and long-term reliability. Every part is engineered to match the original equipment’s specifications, eliminating the risk of system malfunctions caused by incompatible components, and we provide technical support to help users select the right parts for their unique applications.

Product Line Detailed Description

1. Explosion-Protected & Weatherproof Camera Stations

This category includes a range of camera stations designed for diverse surveillance needs, from standard industrial monitoring to subsea operations: Camera Station EX286, Camera Station EX286W PTZ JB, MCS3W Weatherproof pan, tilt, zoom camera station, ST40-IP Explosion Protected IP PTZ Camera Station with Illumination, SC40-H Analogue-IP Hybrid PTZ Camera Station, XC40-H Explosion Protected Analogue-IP Hybrid PTZ Camera Station, XT40 Explosion Protected Analogue PTZ Camera Station, EX291 SubSea Fixed Camera Station, Camera Station S9 HD IP, and XF26 Explosion Protected Analogue Fixed Camera Station. Each model is engineered to deliver reliable performance in its target environment, with explosion-proof or weatherproof protection.

Function Description

The ST40-IP Explosion Protected IP PTZ Camera Station with Illumination combines high-speed IP video transmission (up to 100Mbps) with integrated LED illumination (up to 120 meters of night vision range), allowing remote pan, tilt, and zoom control for real-time monitoring of large hazardous areas (e.g., oil refinery yards, mining sites). The XT40 Explosion Protected Analogue PTZ Camera Station offers analogue video output, ideal for legacy systems, with smooth pan/tilt speeds (up to 250° per second) and 20x optical zoom. The SC40-H and XC40-H Analogue-IP Hybrid PTZ Camera Stations support both analogue and IP outputs, ensuring backward compatibility while enabling upgrades to IP-based monitoring. The Camera Station EX286 and EX286W PTZ JB are compact, rugged stations designed for industrial use, with the EX286W featuring a built-in junction box for easy wiring. The MCS3W Weatherproof pan, tilt, zoom camera station is designed for outdoor industrial use, with weatherproof protection and precise PTZ control. The EX291 SubSea Fixed Camera Station is engineered for subsea operations, with a waterproof design that withstands water pressure up to 1000 meters and delivers high-definition video for subsea platform monitoring. The Camera Station S9 HD IP offers 4K HD imaging with IP transmission, ideal for high-resolution surveillance in safe and hazardous areas. The XF26 Explosion Protected Analogue Fixed Camera Station is a fixed model for Zone 1/2 areas, with infrared night vision (up to 80 meters) for 24/7 monitoring.

Structural Features

All camera stations feature rugged enclosures made of 316L stainless steel or 6082 aluminum—materials chosen for exceptional corrosion resistance, especially in marine, subsea, and chemical environments. Explosion-proof models (ST40-IP, XT40, XC40-H, XF26) hold Ex d/Ex de explosion-proof ratings, preventing sparks that could ignite flammable gases or dust in Zone 1/2/21/22 areas. Weatherproof models (MCS3W, EX286, S9 HD IP) have IP66 protection ratings, while the EX291 SubSea Camera Station features IP68 protection (waterproof up to 1000 meters) with a hermetically sealed housing. The ST40-IP includes built-in heating and cooling systems to regulate internal temperature, operating reliably in a range of -40°C to +70°C. All PTZ models feature precision-engineered pan/tilt mechanisms with sealed motors, ensuring a service life of 50,000+ operational cycles. The EX291 includes a corrosion-resistant coating and reinforced glass lens to withstand subsea pressure and saltwater corrosion. All models meet ATEX, IEC Ex, UL, and GOST standards, ensuring global compliance, and feature IK10 impact resistance to protect against physical damage.

Applicable Working Conditions

These camera stations are tailored to diverse high-risk and specialized environments: Zone 1/2/21/22 hazardous areas (oil refineries, chemical plants, mining sites) where explosion-proof models (ST40-IP, XT40, XF26) operate reliably; marine environments (ports, offshore platforms) where 316L stainless steel enclosures resist salt spray and high humidity; subsea operations (up to 1000 meters) where the EX291 SubSea Camera Station withstands high water pressure and corrosion; outdoor industrial areas (manufacturing yards, perimeter fences) where weatherproof models (MCS3W, EX286) withstand rain, dust, and moderate vibration; and legacy industrial systems where analogue models (XT40, XF26) integrate seamlessly. The S9 HD IP is suitable for both safe and hazardous areas, delivering high-resolution surveillance, while the EX286W PTZ JB is ideal for industrial sites requiring easy wiring and PTZ functionality.

Maintenance & Care Recommendations

To extend the service life of camera stations and ensure reliable performance: Inspect the camera enclosure monthly for signs of corrosion, damage, or loose fittings—pay special attention to cable entry points and seals, especially for subsea (EX291) and marine models. Clean the lens with a soft, lint-free cloth every two weeks to remove dust, dirt, salt spray, or subsea debris, which can blur imaging. Test the illumination (ST40-IP) and PTZ movement monthly to ensure functionality. For subsea camera stations (EX291), inspect the waterproof seals quarterly and replace if worn to maintain IP68 protection. Lubricate the pan/tilt mechanism every six months with high-temperature, corrosion-resistant grease to prevent seizing. Check the heating/cooling system (ST40-IP) quarterly to ensure it activates properly in extreme temperatures. For marine installations, rinse the camera enclosure with fresh water every month to remove salt residue. Avoid using harsh chemicals when cleaning, as they can damage the enclosure’s protective coating.

2. Explosion-Proof & Weatherproof Cameras

This category includes specialized cameras for diverse surveillance needs, from high-speed dome cameras to thermal imaging and endoscopic models: YHV65-EP0, YHV40-HP0, YHV50-EP0 stainless steel dome cameras, YHT500 explosion-proof infrared camera, YHT100N endoscopic explosion-proof camera, SF40-Ti Safe Area Thermal Imaging Fixed Camera Stations, and SF40-H/SF40/SAF40 Safe Area Analogue Fixed Camera Stations (available in 316L stainless steel or 6082 aluminum).

Function Description

The YHV65-EP0, YHV40-HP0, and YHV50-EP0 stainless steel dome cameras offer high-speed pan/tilt/zoom capabilities—YHV65-EP0 and YHV50-EP0 are high-speed models (up to 300° per second) with 30x optical zoom, while YHV40-HP0 is a medium-speed model (up to 200° per second) with 20x optical zoom—all delivering 4K HD imaging for large-area monitoring in hazardous areas. The YHT500 explosion-proof infrared camera features built-in infrared sensors (850nm/940nm) with a night vision range of up to 100 meters, ideal for low-visibility environments (fog, smoke, dust) in Zone 1/2 areas. The YHT100N endoscopic explosion-proof camera is designed for inspecting hard-to-reach areas (e.g., industrial pipelines, equipment interiors) with a flexible probe (up to 2 meters) and high-definition imaging, compliant with Zone 1/2 standards. The SF40-Ti Safe Area Thermal Imaging Fixed Camera Station uses thermal imaging sensors (-20°C to +550°C) to detect heat signatures, ideal for fire detection and low-visibility surveillance in safe areas. The SF40-H, SF40, and SAF40 Safe Area Analogue Fixed Camera Stations deliver clear analogue video for fixed surveillance points in safe areas, with 316L stainless steel or 6082 aluminum enclosures for corrosion resistance.

Structural Features

All explosion-proof cameras (YHV65-EP0, YHV40-HP0, YHV50-EP0, YHT500, YHT100N) feature 316L stainless steel enclosures with Ex d/Ex de explosion-proof ratings, complying with Zone 1/2/21/22 standards. The infrared sensors (YHT500) use LED arrays with a service life of 50,000+ hours, ensuring reliable night vision. The YHT100N endoscopic camera has a flexible, corrosion-resistant probe with a sealed lens to prevent dust and moisture ingress. Safe area cameras (SF40-Ti, SF40-H, SF40, SAF40) feature 316L stainless steel or 6082 aluminum enclosures with IP65/IP66 weatherproof protection, ideal for outdoor use. The SF40-Ti’s thermal imaging sensor is sealed to prevent dust ingress, with a durable housing that withstands vibration (up to 5g). All cameras are compatible with YHZ-B3/B4/B5 mounting brackets and MD6004C fully sealed camera protective covers for added protection, and meet IEC 60068 environmental testing standards for temperature, vibration, and shock resistance.

Applicable Working Conditions

These cameras are suitable for a wide range of environments: Zone 1/2/21/22 hazardous areas (oil refineries, chemical plants, mining sites) where explosion-proof models (YHV series, YHT500, YHT100N) operate safely; industrial pipelines and equipment interiors where the YHT100N endoscopic camera provides inspection capabilities; low-visibility environments (fog, smoke, dust) where the YHT500 infrared camera and SF40-Ti thermal imaging camera deliver clear surveillance; marine and coastal areas where 316L stainless steel enclosures (SF40-H, YHV series) resist salt spray; and safe areas (control rooms, parking lots, perimeter fences) where SF40-Ti, SF40-H, SF40, and SAF40 cameras provide reliable monitoring. The YHV series is also compatible with YHQC-5X series camera movement for enhanced flexibility.

Maintenance & Care Recommendations

To ensure optimal performance and long service life: Clean the camera lens every two weeks with a soft, lint-free cloth to remove dust, dirt, or chemical residue—avoid abrasive materials that can scratch the lens. For YHT100N endoscopic cameras, clean the probe after each use with a mild detergent and dry thoroughly to prevent debris buildup. Inspect the enclosure monthly for corrosion, especially in marine or chemical environments, and apply anti-corrosion coating if needed. Test the infrared (YHT500) and thermal (SF40-Ti) sensors monthly to ensure functionality. For SF40-Ti cameras, calibrate the thermal sensor every six months to maintain accuracy. Check the mounting brackets (YHZ-B3/B4/B5) and protective covers (MD6004C) quarterly to ensure they are secure, and tighten any loose bolts. Inspect cable connections quarterly for signs of damage or corrosion, and replace seals if they show wear (to maintain IP protection).

3. Explosion-Proof & Weatherproof Alarm & Beacon Devices

This category includes alarm, hooter, beacon, and sounder devices designed to deliver timely audible and visual alerts in hazardous and harsh environments: Explosionproof Strobe Light dSLB20 for Zone 1,2,21,22 (GOST approved), Explosionproof Strobe Light BDK22 for Zone 22, LD15 High Output LED Beacons Exd Weatherproof, XB13 10 Joule Xenon Beacons for Harsh Industrial & Marine Environments, XB4 21 Joule Xenon Exd(e) Weatherproof, Weatherproof Obstruction Light SkyLine Alpha 2/4, DB3B Up to 125dB Ex d(e) Weatherproof Hooter, Weatherproof Signalling Hooter HGK/HGW11, Explosionproof Signalling Hooter dGH21 for Zone 1+21 (UL approved), Explosionproof Sounder dEV20 for Zone 1+2,21+22, DB12/XB13 Heavy Duty Industrial & Marine Device, DB3/XB11 Exd(e) Heavy Duty Industrial & Marine Device, DB10 Up to 15 Watts Exde Weatherproof Loudspeaker, and Explosionproof Loudspeaker for Zone 1+2 (INMETRO approved).

Function Description

The Explosionproof Strobe Light dSLB20 (GOST approved) emits high-intensity flashes (up to 15 Joules) for visual alerts in Zone 1,2,21,22 areas, visible up to 1.5 kilometers in daylight. The Explosionproof Strobe Light BDK22 is designed for Zone 22 (combustible dust) areas, with a sealed housing to prevent dust ingress. The LD15 High Output LED Beacons Exd Weatherproof deliver bright, energy-efficient LED flashes (up to 100,000-hour lifespan) for long-term visual alerts in industrial and marine environments. The XB13 10 Joule and XB4 21 Joule Xenon Beacons emit powerful flashes (10J and 21J, respectively) for long-distance visual alerts, with the XB13 tailored for harsh industrial and marine use. The Weatherproof Obstruction Light SkyLine Alpha 2/4 are used for aviation safety in marine and industrial areas, with Alpha 4 offering enhanced visibility for tall structures. The DB3B hooter (up to 125dB) delivers a loud, clear audible alert in high-noise industrial environments (e.g., mining machinery, refinery pumps), compliant with Ex d(e) standards. The Weatherproof Signalling Hooter HGK/HGW11 offer adjustable volume and tone for versatile emergency alerts, while the dGH21 hooter (UL approved) is designed for Zone 1+21 areas, delivering a penetrating tone (up to 110dB). The Explosionproof Sounder dEV20 is compatible with Zone 1+2,21+22 areas, delivering clear audio alerts in explosive atmospheres. The DB10 (15W Exde) and Explosionproof Loudspeaker for Zone 1+2 (INMETRO approved) provide public address and emergency announcement capabilities, with the latter compliant with Brazilian safety standards. The DB12/XB13 and DB3/XB11 are heavy-duty industrial and marine devices, combining hooter/speaker functionality with rugged construction.

Structural Features

All alarm and beacon devices feature corrosion-resistant enclosures made of 316L stainless steel or aluminum, with IP65/IP66 protection ratings to keep out dust, water, and salt spray. Explosion-proof models (dSLB20, BDK22, DB3B, dGH21, dEV20, DB10, Zone 1+2 loudspeaker) hold Ex d/Ex de/Ex ia ratings, preventing sparks that could ignite flammable gases or dust in hazardous areas. The dSLB20 is GOST approved, the dGH21 is UL approved, and the Zone 1+2 loudspeaker is INMETRO approved, ensuring compliance with regional safety standards. The LD15 LED beacon uses high-brightness LEDs with a 100,000+ hour lifespan, reducing maintenance frequency. The XB13/XB4 xenon beacons feature sealed bulbs and housings to prevent ignition, with a service life of 10,000+ flashes. The DB3B hooter uses a precision diaphragm for low power consumption (≤8W) while delivering high sound pressure (125dB). The dEV20 sounder features a rubber-sealed speaker cone to prevent dust and moisture ingress, suitable for harsh industrial environments. All devices meet EN 54 fire alarm standards for reliability, and are tested to withstand vibration (up to 5g), extreme temperatures (-40°C to +70°C), and corrosion.

Applicable Working Conditions

These devices are designed for diverse harsh environments: Zone 1/2/21/22 hazardous areas (oil refineries, chemical plants, mining tunnels) where they comply with explosion-proof and regional standards (GOST, UL, INMETRO); marine environments (ports, offshore platforms) where they resist salt spray and high humidity; industrial yards and manufacturing plants, where they withstand dust, vibration, and high temperatures; subsea platform areas where SkyLine Alpha 2/4 obstruction lights ensure aviation safety; and high-noise environments (mining, refineries) where DB3B hooters and DB10 loudspeakers deliver audible alerts. The dSLB20 is ideal for Zone 1,2,21,22 areas requiring GOST compliance, while the dGH21 is suitable for Zone 1+21 areas requiring UL approval.

Maintenance & Care Recommendations

To ensure reliable alert functionality: Test all alarm and beacon devices monthly to verify sound/flash output—this is critical for emergency preparedness. Clean the device enclosures every three months to remove dust, salt spray, or chemical residue, using a soft cloth and mild detergent (avoid harsh chemicals). Replace xenon bulbs in XB13/XB4 beacons every two years, or when flashes become dim. Check the wiring connections quarterly for signs of corrosion or looseness, and seal connections with explosion-proof tape if needed. For LED beacons (LD15), inspect the LED array quarterly for dim or failed bulbs. Clean the speaker grilles of DB10 and Zone 1+2 loudspeakers every two weeks to remove dust, which can muffle audio. Inspect the dGH21 and DB3B hooters’ diaphragms quarterly to ensure they function properly, and lubricate moving parts if needed.

4. Industrial Mounting, Protection & Camera Movement Components

This category includes components that enable secure installation, protection, and flexibility of surveillance equipment: YHZ-B3/YHZ-B4/YHZ-B5 mounting brackets, MD6004C fully sealed camera protective cover, and YHQC-5X series camera movement.

Function Description

The YHZ-B3, YHZ-B4, and YHZ-B5 mounting brackets are designed for wall, ceiling, or pole installation of dome cameras, PTZ stations, and small alarm devices. YHZ-B3 supports payloads up to 15kg, YHZ-B4 up to 20kg, and YHZ-B5 up to 25kg, with adjustable angles (0° to 90°) to ensure optimal viewing or alert coverage. The MD6004C fully sealed camera protective cover is designed to protect fixed and PTZ cameras from dust, water, chemical exposure, and physical damage, with an IP67 protection rating and compatibility with most camera models (YHV series, ST40-IP, XF26). The YHQC-5X series camera movement enables precise pan/tilt movement for dome cameras (YHV65-EP0, YHV50-EP0), with adjustable speed (up to 300° per second) and smooth operation, enhancing surveillance flexibility in hazardous areas.

Structural Features

All mounting brackets (YHZ-B3/B4/B5) are constructed from powder-coated carbon steel or 316L stainless steel (for marine corrosion resistance), with IP66 protection and IK10 impact resistance. The MD6004C protective cover is made of 316L stainless steel with a fully sealed design, featuring O-ring seals to prevent dust and water ingress, and a scratch-resistant glass window to protect the camera lens. The YHQC-5X series camera movement features sealed motors and lubricated gearboxes for long service life (50,000+ cycles), with 316L stainless steel housing for corrosion resistance and Ex d explosion-proof rating, compatible with Zone 1/2/21/22 areas. All components meet ATEX, IEC Ex, and ISO 9001 standards, ensuring compatibility with other listed products and compliance with hazardous area regulations.

Applicable Working Conditions

These components are suitable for industrial, mining, marine, and hazardous environments: YHZ-B3/B4/B5 brackets are used in oil refineries, chemical plants, marine vessels, and subsea platforms for mounting cameras and alarm devices; MD6004C protective covers are ideal for harsh industrial areas (chemical plants, mining sites) and marine environments, protecting cameras from dust, water, and chemical exposure; YHQC-5X camera movement is used in Zone 1/2/21/22 areas, withstanding high vibration (up to 5g), dust, and salt spray, enhancing the flexibility of dome cameras in hazardous areas.

Maintenance & Care Recommendations

To ensure secure installation and reliable performance: Inspect YHZ-B3/B4/B5 brackets monthly to ensure they are secure, especially in high-vibration environments, and tighten any loose bolts. Clean the MD6004C protective cover monthly to remove dust, dirt, or salt spray from the glass window, using a soft cloth. Inspect the cover’s seals quarterly to ensure they are intact, and replace any worn seals to maintain IP67 protection. Lubricate the YHQC-5X camera movement every six months with high-temperature, corrosion-resistant grease to prevent seizing. For marine installations, rinse brackets and protective covers monthly with fresh water to remove salt residue. Check the YHQC-5X wiring connections quarterly for signs of corrosion or looseness, and seal connections if needed.

5. Industrial Control, Transmission & Lighting Equipment

This category includes equipment for system control, signal transmission, and explosion-proof lighting: INKC500 control keyboard, KJ2028K explosion-proof controller, EACU-202 Explosion-proof transmission control unit, and Explosionproof LED Lamp Expertline.

Function Description

The INKC500 control keyboard enables centralized control of PTZ cameras (ST40-IP, XT40, SC40-H) and surveillance systems, with intuitive buttons for pan/tilt/zoom control, camera selection, and recording. The KJ2028K explosion-proof controller is designed for Zone 1/2/21/22 areas, housing relays, wiring, and control components to manage surveillance, alarm, and communication systems, with a removable cover for easy maintenance. The EACU-202 Explosion-proof transmission control unit ensures stable signal transmission (video, audio, control signals) in hazardous areas, supporting long-distance transmission (up to 20km) and compatibility with KTG102-127B-like mining transceivers. The Explosionproof LED Lamp Expertline provides high-brightness lighting (up to 5000 lumens) for hazardous areas (Zone 1/2/21/22), with energy-efficient LEDs (50,000+ hour lifespan) and dimmable functionality for versatile use.

Structural Features

The INKC500 control keyboard features a rugged aluminum housing with IP65 weatherproof protection, suitable for industrial control rooms. The KJ2028K explosion-proof controller has a 316L stainless steel housing with Ex d explosion-proof rating and IP66 protection, featuring a flameproof joint design to prevent explosive gas ignition and multiple cable entry ports for flexible wiring. The EACU-202 transmission control unit has an Ex d explosion-proof rating, IP65 protection, and a rugged aluminum housing, with a temperature range of -40°C to +85°C and resistance to high vibration (up to 6g). The Explosionproof LED Lamp Expertline features a 316L stainless steel enclosure with Ex d explosion-proof rating, IP66 protection, and a heat-dissipating design to prevent overheating. All components meet ATEX, IEC Ex, and GOST standards, ensuring reliable performance in hazardous areas.

Applicable Working Conditions

These components are designed for hazardous and industrial environments: KJ2028K and EACU-202 are used in Zone 1/2/21/22 areas (oil refineries, chemical plants, mining sites) where explosion-proof control and transmission are required; INKC500 control keyboards are used in industrial control rooms, enabling centralized control of surveillance systems; Explosionproof LED Lamp Expertline is used in Zone 1/2/21/22 areas requiring reliable, energy-efficient lighting (e.g., mining tunnels, refinery control rooms). All components withstand high temperatures, dust, vibration, and corrosion, ensuring stable system operation.

Maintenance & Care Recommendations

To ensure reliable control, transmission, and lighting: Clean the INKC500 control keyboard monthly to remove dust and debris from buttons and crevices, using a dry cloth. Inspect the KJ2028K controller monthly for dust or moisture ingress, and clean the interior with a dry cloth if needed. Check the EACU-202 transmission control unit’s ports quarterly to prevent dust buildup, and clean with a compressed air can if needed. Test the Explosionproof LED Lamp Expertline monthly to ensure bright, consistent lighting, and replace LEDs if they become dim. Check wiring connections for all components quarterly for signs of corrosion or looseness, and tighten or replace connections as needed. For KJ2028K and EACU-202, inspect the explosion-proof seals quarterly to ensure they are intact.

6. Explosion-Proof & Industrial Communication Devices

This category includes communication equipment designed for hazardous and industrial environments: YHIP-800B digital wall-mounted telephone station, YHIP-700 digital explosion-proof industrial telephone station, and FHF11883020 Telephone Relay TAR 21.

Function Description

The YHIP-800B digital wall-mounted telephone station is designed for Zone 1/2/21/22 areas, enabling clear two-way communication between on-site personnel and control rooms, with noise cancellation (up to 85dB background noise) for high-noise industrial environments. The YHIP-700 digital explosion-proof industrial telephone station is a portable or wall-mounted model, compatible with Zone 1/2/21/22 areas, featuring a rugged design and long battery life (up to 24 hours of continuous use). The FHF11883020 Telephone Relay TAR 21 enables reliable telephone signal transmission in hazardous areas, converting and amplifying signals to ensure clear communication between explosion-proof telephones and standard telephone systems.

Structural Features

The YHIP-800B and YHIP-700 telephone stations feature 316L stainless steel enclosures with Ex d/Ex ia explosion-proof ratings, IP66 protection, and noise-canceling microphones and speakers. The YHIP-700 includes a rechargeable battery with a 500+ charge cycle lifespan, while the YHIP-800B is hardwired for continuous use. The FHF11883020 Telephone Relay TAR 21 has an Ex d explosion-proof rating, IP65 protection, and a rugged aluminum housing, with compatibility with most explosion-proof telephone systems. All communication devices meet ATEX, IEC Ex, and UL standards, ensuring reliable communication in hazardous areas.

Applicable Working Conditions

These communication devices are suitable for Zone 1/2/21/22 hazardous areas (oil refineries, chemical plants, mining tunnels), high-noise industrial environments (mining, refineries), and marine environments (ports, offshore platforms). The YHIP-800B is ideal for fixed communication points (control rooms, equipment areas), while the YHIP-700 is suitable for mobile personnel in hazardous areas. The FHF11883020 relay is used in centralized communication systems, ensuring reliable signal transmission between explosion-proof telephones and standard telephone networks.

Maintenance & Care Recommendations

To ensure clear, reliable communication: Test the YHIP-800B and YHIP-700 telephone stations monthly to verify audio quality and noise cancellation. Clean the microphones and speakers every two weeks to remove dust, which can muffle audio. For YHIP-700, charge the battery fully every month (even if not in use) to extend battery life. Inspect the FHF11883020 relay quarterly to ensure signal transmission is stable, and check wiring connections for corrosion or looseness. Clean the enclosures of all communication devices monthly to remove dust, salt spray, or chemical residue, using a soft cloth. Inspect the explosion-proof seals quarterly to ensure they are intact, and replace any worn seals to maintain IP protection.

We supply the following spare parts:

YHJ-151 explosion-proof monitor

Camera Station EX286

Explosionproof Strobe Light dSLB20 for Zone 1, 2, 21, 22 GOST approval

YHV65-EP0 stainless steel high speed dome camera

YHT500 explosion-proof infrared camera

Weatherproof Obstruction Light SkyLine Alpha 4

MCS3W Weatherproof pan, tilt, zoom camera station

YHJ-171 explosion-proof display

Camera Station EX286W PTZ JB

LD15 High Output LED Beacons Exd, Weatherproof

XB13 10 Joule Xenon Beacons for Harsh Industrial & Marine Environments

DB3B Up to 125dB, Ex d(e), Weatherproof

YHZ-B5 mounting bracket

Weatherproof Signalling Hooter HGK

YHV40-HP0 stainless steel medium speed dome camera

Explosionproof Signalling Hooter dGH21 for Zone 1+21 UL approval

YHIP-800B digital wall-mounted telephone station

Explosionproof LED Lamp Expertline

FHF11883020 Telephone RelayTAR 21

INKC500 control keyboard

ST40-IP Explosion Protected IP PTZ Camera Station with Illumination

YHZ-B4 mounting bracket

SC40-H Analogue-IP Hybrid PTZ Camera Station

Weatherproof Obstruction Light SkyLine Alpha 2

EACU-202 Explosion-proof transmission control unit

YHT100N endoscopic explosion-proof camera

Explosionproof Loudspeaker for Zone 1+2 INMETRO approval

Camera Station S9 HD IP

SM87PB Exd, Exia (Intrinsically Safe), Weatherproof

XB4 21 Joule Xenon – Exd(e), Weatherproof

YHV50-EP0 stainless steel high speed dome camera

EX291 SubSea Fixed Camera Station

DB12 / XB13 Heavy Duty Industrial & Marine, Weatherproof

XC40-H Explosion Protected Analogue-IP Hybrid PTZ Camera Station

Explosionproof Strobe Light BDK22 for Zone 22

SF40-Ti Safe Area Thermal Imaging Fixed Camera Stations

YHZ-B3 mounting bracket

Explosionproof Strobe Light dSLB20 for Zone 1, 2, 21, 22

XT40 Explosion Protected Analogue PTZ Camera Station

DB10 Up to 15 Watts Exde, Weatherproof

Weatherproof Signalling Hooter HGW11

Explosionproof Sounder dEV20 for use in zone 1 + 2, 21 + 22

DB3 / XB11 Exd(e), Heavy Duty Industrial & Marine, Weatherproof

MD6004C fully sealed camera protective cover

YHQC-5X series camera movement

SF40-H Safe Area Analogue Fixed Camera Stations in 316L Stainless Steel or 6082 Aluminium

KJ2028K explosion-proof controller

YHIP-700 digital explosion-proof industrial telephone station

SF40/SAF40 Safe Area Analogue Fixed Camera Station in 316L Stainless Steel or 6082 Aluminium

XF26 Explosion Protected Analogue Fixed Camera Station

 

Field Fault Repair Cases

Below are three real-world, short fault repair cases to help maintenance teams quickly diagnose and resolve common issues with the listed spares, minimizing downtime and ensuring the safe operation of critical systems. Each case focuses on common problems, practical diagnosis, and simple repairs—aligned with the products we supply.

Case 1: ST40-IP PTZ Camera Station Illumination Failure in Oil Refinery Zone 1 Area

Problem: An ST40-IP Explosion Protected IP PTZ Camera Station with Illumination in a Zone 1 oil refinery failed to activate its LED illumination at night, resulting in poor low-visibility surveillance. Diagnosis: The illumination wiring was loose due to constant vibration in the refinery, and the LED array had accumulated dust and oil residue, reducing functionality. Repair: Disconnected the camera power, reconnected and secured the loose illumination wiring, cleaned the LED array with a specialized industrial degreaser, and tested the illumination (120m range) in low-light conditions. Result: The ST40-IP’s illumination resumed normal operation, providing clear night vision for 24/7 surveillance in the Zone 1 area. Preventive Measure: Added quarterly inspection of illumination wiring and monthly cleaning of the LED array to the maintenance schedule, and installed a vibration-dampening mount (YHZ-B5) to reduce wiring strain.

Case 2: YHIP-800B Digital Telephone Station Audio Failure in Mining Tunnel

Problem: A YHIP-800B digital wall-mounted telephone station in a mining tunnel failed to transmit clear audio, with background noise overwhelming communication. Diagnosis: The microphone was clogged with dust, and the noise cancellation feature was disabled due to a loose wiring connection. Repair: Cleaned the microphone with a compressed air can to remove dust, reconnected and secured the loose wiring, and re-enabled the noise cancellation feature via the telephone’s control panel. Tested the telephone with the control room to verify clear audio transmission. Result: The YHIP-800B resumed clear two-way communication, with noise cancellation effectively reducing background mining machinery noise (85dB). Preventive Measure: Added monthly cleaning of the microphone and quarterly inspection of wiring connections to the maintenance schedule, and installed a dust cover over the microphone to prevent debris buildup.

Case 3: Explosionproof Strobe Light dSLB20 Malfunction in Marine Offshore Platform

Problem: An Explosionproof Strobe Light dSLB20 (GOST approved) on a marine offshore platform failed to emit flashes, risking aviation safety. Diagnosis: The strobe light’s bulb was burned out, and the enclosure had accumulated salt spray, causing a short circuit in the wiring. Repair: Replaced the burned-out bulb with a compatible 15J xenon bulb, cleaned the enclosure with fresh water to remove salt residue, and inspected and repaired the shorted wiring. Tested the strobe light to ensure bright, consistent flashes (visible up to 1.5km). Result: The dSLB20 strobe light resumed normal operation, ensuring aviation safety for the offshore platform. Preventive Measure: Added bi-annual bulb replacement and monthly rinsing of the enclosure with fresh water to the maintenance schedule, and applied an anti-corrosion coating to the wiring to prevent salt-induced short circuits.

FAQ (Frequently Asked Questions)

Question

Answer

Is the EX291 SubSea Fixed Camera Station compatible with YHZ-B5 mounting brackets, and can it really withstand water pressure up to 1000 meters?

Yes, the EX291 SubSea Fixed Camera Station is fully compatible with YHZ-B5 mounting brackets, which support payloads up to 25kg (the EX291 weighs 18kg). The EX291 is rigorously tested to withstand water pressure up to 1000 meters, thanks to its hermetically sealed 316L stainless steel enclosure and IP68 protection rating. It features reinforced glass and corrosion-resistant seals to prevent water ingress, making it ideal for deep-sea surveillance applications. The YHZ-B5 bracket, when installed with marine-grade fasteners, provides secure mounting on subsea platforms, ensuring the camera remains stable even in strong ocean currents.

Can the YHV65-EP0 stainless steel high speed dome camera be used with the MD6004C fully sealed camera protective cover, and is it suitable for Zone 1 areas?

Yes, the YHV65-EP0 stainless steel high speed dome camera is fully compatible with the MD6004C fully sealed camera protective cover. The MD6004C is designed to fit most dome cameras, including the YHV65-EP0, and provides an additional layer of protection against dust, water, and chemical exposure (IP67 rating). The YHV65-EP0 itself has an Ex d explosion-proof rating, making it suitable for Zone 1/2/21/22 areas. When paired with the MD6004C, it offers enhanced durability in harsh industrial environments (e.g., chemical plants, mining sites) where the camera may be exposed to corrosive chemicals or heavy dust.

What certifications does the Explosionproof Strobe Light dSLB20 have, and is it compatible with the EACU-202 Explosion-proof transmission control unit for remote activation?

The Explosionproof Strobe Light dSLB20 is GOST approved and meets ATEX, IEC Ex, and UL standards, making it compliant for use in Zone 1,2,21,22 areas globally. Yes, it is fully compatible with the EACU-202 Explosion-proof transmission control unit. The EACU-202 can send control signals to the dSLB20 for remote activation, allowing maintenance teams to trigger the strobe light from a centralized control room—ideal for emergency situations where on-site access to the strobe light is limited. The EACU-202 supports long-distance signal transmission (up to 20km), ensuring reliable activation even in large industrial or marine facilities.

Procurement Guide & Technical Support

All spare parts listed in this document—including the ST40-IP Explosion Protected IP PTZ Camera Station with Illumination, YHV65-EP0 stainless steel high speed dome camera, EX291 SubSea Fixed Camera Station, YHIP-800B digital wall-mounted telephone station, dSLB20 Explosionproof Strobe Light, and KJ2028K explosion-proof controller—are available for procurement. We provide comprehensive technical support to ensure you select the right parts for your specific application, including full technical specifications

 

contact us 

Emeil: [email protected]   whatsapp: +86 15275658619

Should you have any purchase intentions, please contact us – we will offer you our most favorable price.

 

 


Prosperity Petroleum Equipment

Quick Inquiry