Core Application & Target User Overview
This guide covers professional electric contact pressure gauges of YX, YTNX, and YXC series, compatible with industrial equipment and systems including hydraulic/pneumatic machinery, boiler systems, water supply pipelines, chemical reactors, and oil & gas transmission lines. Tailored for plant maintenance engineers, process control technicians, power generation enterprises, and chemical processing plants, it addresses the critical demand for pressure measurement with automatic alarm and control functions to avoid equipment overpressure damage, production accidents, or process disruption caused by manual monitoring delays. All products comply with EN 837-1 (pressure gauge technical specifications), IEC 60947-1 (electrical contact safety standards), and IP65 protection rating requirements, undergoing rigorous accuracy calibration and vibration resistance testing to ensure reliable performance in harsh industrial environments (vibration, humidity, and corrosive gas).
YX Series Electric Contact Pressure Gauges
YX Series Electric Contact Pressure Gauges integrate pressure measurement and electrical control functions, triggering alarm or control signals when pressure reaches preset upper/lower limits. They are widely used in general industrial pressure monitoring scenarios such as water supply systems and ordinary hydraulic equipment. Premature failure (contact jitter, accuracy drift) can lead to false alarms or failure to trigger protection measures, causing equipment damage. Our YX gauges adopt silver-plated electrical contacts and precision movement structures, ensuring stable contact performance and measurement accuracy class up to 1.5.
Field Application Case
A food processing plant encountered frequent false alarms with ordinary pressure gauges in their steam boiler pressure monitoring system, leading to unnecessary production interruptions. After replacing with YX-100Z electric contact pressure gauges (complying with EN 837-1), the false alarm rate dropped to zero. The gauges accurately triggered alarm signals when steam pressure exceeded 1.2MPa, ensuring boiler operation safety and reducing production downtime by 20% within 6 months.
Serial No. | Product Model | Material | Main Wear Reasons | Damage Prevention Notes |
1 | YX-60, YX-60Z, YX-60ZT | Case: ABS engineering plastic (UL94 V-0); Movement: Copper alloy (CuZn39Pb3); Bourdon tube: Brass (H62); Electrical contacts: Silver-plated copper alloy; Window: Acrylic glass; Z/ZT models: Magnetic anti-vibration device | 1. Contact oxidation and poor conductivity from humid environments (relative humidity >85%); 2. Movement jamming from vibration in pump vicinity | 1. Install the gauge in a moisture-proof control cabinet, seal cable entries with silicone rubber; 2. For Z/ZT models, check magnetic anti-vibration device tightness monthly |
2 | YX-100, YX-100Z, YX-100ZT | Case: Cast iron (HT200) with anti-rust coating; Movement: Copper alloy (CuZn39Pb3); Bourdon tube: Phosphor bronze (QSn6.5-0.1); Electrical contacts: Silver-plated copper alloy; Window: Toughened glass; Z/ZT models: Magnetic anti-vibration device | 1. Bourdon tube fatigue deformation from frequent pressure cycling (≥10⁴ cycles); 2. Accuracy drift from installation tilt (angle >5°) | 1. Conduct accuracy calibration every 6 months per EN 837-1, replace Bourdon tube if drift exceeds 2% of full scale; 2. Install horizontally (tilt angle ≤3°) using a level meter |
3 | YX-150, YX-150Z, YX-150ZT | Case: Cast aluminum alloy (AlSi10Mg); Movement: Copper alloy (CuZn39Pb3); Bourdon tube: Phosphor bronze (QSn6.5-0.1); Electrical contacts: Silver-plated copper alloy; Window: Toughened glass; Z/ZT models: Magnetic anti-vibration device | 1. Case corrosion from corrosive gas in chemical plant environments; 2. Contact jitter from voltage fluctuations in the control circuit | 1. Apply anti-corrosion paint to the case annually; 2. Install a voltage stabilizer in the control circuit to maintain voltage fluctuation ≤±5% |
YTNX Series Shock-Proof Electric Contact Pressure Gauges
YTNX Series Shock-Proof Electric Contact Pressure Gauges are specialized for high-vibration industrial scenarios such as construction machinery, mining equipment, and high-pressure pumps. The internal filling of shock-proof oil and reinforced movement structure effectively reduce vibration impact, ensuring stable pressure measurement and contact signal output. Premature failure (oil leakage, contact damage) can lead to loss of pressure monitoring and control functions, causing equipment overload. Our YTNX gauges adopt high-seal oil-filled structures and wear-resistant contacts, ensuring reliable operation in strong vibration environments (vibration frequency 10-50Hz).
Serial No. | Product Model | Material | Main Wear Reasons | Damage Prevention Notes |
1 | YTNX-100, YTNX-100Z, YTNX-100ZT | Case: 304 stainless steel; Movement: 316L stainless steel; Bourdon tube: 316L stainless steel; Electrical contacts: Silver-plated nickel alloy; Window: Toughened glass; Shock-proof oil: Silicone oil; Z/ZT models: Enhanced magnetic anti-vibration device | 1. Oil leakage from seal aging in high-temperature environments (exceeding 80°C); 2. Contact wear from frequent signal switching (≥10⁵ times) | 1. Control ambient temperature ≤60°C, install heat insulation pads if near high-temperature components; 2. Check contact wear status quarterly, replace contacts if wear depth exceeds 0.2mm |
2 | YTNX-150, YTNX-150Z, YTNX-150ZT | Case: 304 stainless steel; Movement: 316L stainless steel; Bourdon tube: 316L stainless steel; Electrical contacts: Silver-plated nickel alloy; Window: Toughened glass; Shock-proof oil: Silicone oil; Z/ZT models: Enhanced magnetic anti-vibration device | 1. Bourdon tube damage from pressure shock (exceeding 120% of full scale); 2. Window fogging from temperature difference-induced condensation | 1. Install a pressure relief valve upstream to limit pressure shock to ≤110% of full scale; 2. Ensure the gauge is fully sealed, replace aging seals immediately if fogging occurs |
YXC Series Magnetism Electric Contact Pressure Gauges
YXC Series Magnetism Electric Contact Pressure Gauges adopt magnetic assistance technology to ensure reliable contact switching, avoiding contact bounce and arcing. They are suitable for precision pressure control scenarios such as chemical reactors, pharmaceutical equipment, and electronic manufacturing cleanrooms. Premature failure (magnetic weakening, accuracy deviation) can lead to imprecise pressure control, affecting product quality. Our YXC gauges adopt high-performance permanent magnets and precision-calibrated movements, ensuring contact switching reliability and measurement accuracy class up to 1.0.
Serial No. | Product Model | Material | Main Wear Reasons | Damage Prevention Notes |
1 | YXC-100, YXC-100Z, YXC-100ZT | Case: 304 stainless steel; Movement: 316L stainless steel; Bourdon tube: 316L stainless steel; Electrical contacts: Silver-plated tungsten alloy; Magnet: Neodymium permanent magnet; Window: Toughened glass; Z/ZT models: Magnetic anti-vibration device | 1. Magnetic weakening from long-term exposure to strong electromagnetic fields; 2. Contact arcing damage from improper load matching | 1. Install at least 1.5m away from high-voltage equipment or electromagnetic coils; 2. Match the contact load with the gauge's rated electrical parameters (≤AC 220V/5A), install an arc suppression device if necessary |
2 | YXC-150, YXC-150Z, YXC-150ZT | Case: 304 stainless steel; Movement: 316L stainless steel; Bourdon tube: 316L stainless steel; Electrical contacts: Silver-plated tungsten alloy; Magnet: Neodymium permanent magnet; Window: Toughened glass; Z/ZT models: Magnetic anti-vibration device | 1. Movement jamming from dust accumulation in cleanroom environments (non-compliant with ISO 14644-1 Class 8); 2. Accuracy drift from media temperature changes (exceeding 50°C) | 1. Install a dust cover compatible with cleanroom standards, clean the gauge surface weekly with alcohol; 2. Install a heat exchanger if media temperature exceeds 40°C to isolate the gauge from high-temperature media |
Procurement & Technical Support Guidelines
Selecting the right electric contact pressure gauge is critical to ensuring the safety and stability of industrial pressure control systems. Our YX, YTNX, and YXC series gauges fully comply with EN 837-1 and IEC 60947-1 standards, with complete accuracy calibration certificates, electrical performance test reports, and material compatibility documents. We provide professional technical support, including gauge selection based on working environment (vibration, humidity, corrosion), pressure range, and control requirements, on-site installation and wiring guidance, and regular maintenance and calibration services. Whether you need single-gauge replacements, bulk inventory, or customized pressure control solutions for special processes, our team is dedicated to delivering reliable products and tailored services. Contact us today to discuss your electric contact pressure gauge requirements and get optimized procurement and application solutions.