06 Feb 2026

Parts for Lanzhou LS Mud Pump (107.11.01.00)

1. Introduction & Core Purpose

This guide is specifically tailored for the Lanzhou LS Mud Pump, focusing on the 107.11.01.00 series parts—encompassing frame assemblies, lubrication systems, power transmission components, sealing elements, fasteners, and auxiliary parts. It addresses the distinct needs of two key user groups: procurement teams requiring model-accurate, standard-compliant parts to eliminate mismatch risks, reduce procurement costs, and ensure compatibility with the pump’s original configuration; and on-site maintenance/technical personnel seeking practical, actionable guidance for fault troubleshooting, component protection, and extending the pump’s service life. The core purpose is to serve as a comprehensive dual-reference document, supporting compliant procurement processes while resolving real-world technical challenges, ensuring the Lanzhou LS Mud Pump maintains reliable, high-efficiency operation in heavy-duty industrial scenarios.

2. Product Overview

The 107.11.01.00 series parts are original-matched core components designed exclusively for the Lanzhou LS Mud Pump, covering critical functional categories: structural supports (frame 107.11.91.00-1, frame assemble 107.11.600.00-1, frame assy 107.11.90.00), power transmission (drive shaft assy 107.11.10.00, crank shaft assy 107.11.20.00, intermediate rod 107.11.01.02), lubrication systems (forced lubrication system 107.11.40.00, spray lubrication system 107.11.30.00, spray pump system 107.11.101.00), sealing elements (gaskets, single lip oil seal 107.11.97.00, packing box 107.11.96.03), fasteners (bolts, nuts, washers), and auxiliary parts (dipstick oil lever 107.11.95.00, oil box 107.11.60.00, water retainer 107.11.70.00, plugs, rubber washers). All parts adhere to national and industrial standards (GB, JB), ensuring dimensional precision, material compatibility, and durability that align with the LS Mud Pump’s heavy-duty operational demands in harsh working environments, such as drilling sites and mining operations.

3. Functional Description

3.1 Structural Support

Frame (107.11.91.00-1), frame assemble (107.11.600.00-1), and frame assy (107.11.90.00) serve as the pump’s foundational structure, providing stable load-bearing and precise installation positioning for internal transmission and lubrication components. These parts resist deformation under high vibration and extreme pressure—key challenges in mud pump operation—maintaining alignment of crank shafts, drive shafts, and crossheads to prevent component interference, power loss, and potential equipment damage.

3.2 Power Transmission

The drive shaft assy (107.11.10.00), crank shaft assy (107.11.20.00), and intermediate rod (107.11.01.02) form the core power transmission chain, converting rotational energy from the motor into reciprocating motion for the pump’s mud conveying mechanism. Crosshead guide upper (107.11.90.05) and lower (107.11.90.03) ensure smooth, precise movement of crossheads, reducing frictional wear and extending the service life of key transmission components, which are critical for consistent pump performance.

3.3 Lubrication & Sealing

Forced lubrication system (107.11.40.00), spray lubrication system (107.11.30.00), and spray pump system (107.11.101.00) deliver targeted lubrication to rotating and sliding parts (bearings, gears, crossheads), minimizing friction and preventing premature wear—essential for reducing maintenance frequency. Oil box (107.11.60.00), oil tubing (107.11.90.08), and dipstick oil lever (107.11.95.00) manage lubricant storage, delivery, and level monitoring, ensuring the system always has sufficient lubrication. Gaskets, single lip oil seals (107.11.97.00), and packing boxes (107.11.96.03) prevent lubricant leakage and external contamination (dust, moisture, mud), protecting internal components from corrosion and damage.

3.4 Fastening & Auxiliary Functions

Fasteners—including bolts (GB5783-86, 107.11.99.00), nuts (GB6170-86), and washers (GB93-87, GB97.1-85)—secure all components, ensuring assembly stability under high vibration. Pins (GB119-86), wires, and water retainers (107.11.70.00) provide auxiliary fixing and protection, preventing part detachment and water ingress that could compromise the lubrication system. Covers (107.11.93.00-1), windows covers (107.04.90.07, 107.04.90.03), and plugs (JB1000-77 M60x2) shield internal parts from external debris and environmental damage, maintaining component integrity. Rubber washers (D3-4-67) enhance sealing performance for plugs and covers, further preventing leakage.

4. Structural Features

The 107.11.01.00 series parts adopt a modular design, facilitating easy disassembly, assembly, and replacement to minimize maintenance downtime and labor costs—critical for maximizing pump availability in continuous operation scenarios. Structural components (frame, frame assy) are crafted from high-strength carbon steel or alloy steel, treated with quenching and tempering to enhance rigidity and fatigue resistance in compliance with GB/T 3077-2015. Lubrication system parts feature precision-machined internal passages for uniform lubricant distribution, ensuring no critical components are under-lubricated. Sealing components use oil-resistant, asbestos-free rubber or high-quality metal materials to adapt to varying pressure and temperature conditions. Fasteners undergo surface galvanization or anti-rust coating, improving corrosion resistance in humid, dusty industrial environments.

5. Application Conditions

These parts are engineered specifically for the Lanzhou LS Mud Pump, widely used in oil & gas drilling, mining exploration, mud transportation, and industrial wastewater treatment. They perform reliably in extreme working conditions, including ambient temperatures ranging from -25°C to 65°C, operating pressures up to 40MPa, and high-vibration (≤ 4.0mm/s) and dusty environments. The parts maintain stability in humid, corrosive settings (exposed to drilling mud, mine water, and chemical media) and meet the continuous operation requirements of heavy-duty mud pumps in industrial applications, where reliability and durability are critical.

6. Maintenance Recommendations

6.1 Routine Inspection

Conduct daily checks of lubricant levels using the dipstick oil lever (107.11.95.00) and inspect for leakage from gaskets, oil seals, and oil tubings. Inspect fasteners weekly for tightness, retightening per standard torque specifications (GB/T 3098.1-2010) if loose. Monthly, examine frame components and crosshead guides for deformation or wear, verify crosshead movement for smoothness, and clean filters in the lubrication system to prevent clogging, which could lead to component failure.

6.2 Regular Replacement

Replace lubricants every 800 working hours, cleaning the oil box and lubrication passages to avoid contamination. Replace gaskets after each disassembly or every 600 working hours; replace single lip oil seals (107.11.97.00) and packing boxes (107.11.96.03) every 1200 working hours or immediately if leakage occurs. Replace fasteners every 2000 working hours or if thread damage, corrosion, or fatigue is detected, and replace worn crosshead guides to prevent jamming.

6.3 Storage & Handling

Store parts in a dry, well-ventilated warehouse, avoiding direct sunlight and humid conditions. Seal gaskets and oil seals in airtight packaging to prevent aging and deterioration. Use specialized lifting equipment for heavy components (frame assy, crank shaft assy) to avoid impact damage. Clean all parts thoroughly to remove debris and rust before installation, ensuring precise fit and optimal performance, as even small contaminants can cause premature wear.

Frame assemble

107.11.600.00-1

Plug

JB1000-77 ( M60x2)

Rubber washer

D3-4-67 (62*75 )

Forced lubrcation system

107.11.40.00

Dipstick oil lever

107.11.95.00

Rubber washer

D3-4-67 (22*32 )

Cover

107.1 U3.00-1

Nut

GB6170-86 (M16)

Plate

107.11.90.27

Pipe

107.11.90.29 (Ø2525x2.5 L=30)

Bolt

107. 11.99.00 (M16)

Drive shaft assy

107.11.10.00

Crank shaft assy

107.11.20.00

Frame

107.11.91.00-1

Spray lubcrcatioi systom

107.11.30.00

Gasket

107.11.90.23 V0.2 50x400

Gasket

107.11.90.24 (50.1 50x400)

Gasket

107.11.90.25 (50.05 50*400)

Gasket

107.11.90.32 ( 58)

Windows cover

107.04.90.07 ( 56)

Oil tubing

107. W. 90.08 (*20x1)

Bolt

GB5783-86 (M12*25)

Rasher

GB93-87 (12)

Oil box

107.11.60.00

Bolt

GB5783-87 (M20x55)

Washer

GB93-87 (20)

Gasket

107.11.90.33

Windows cover

107.04.90.03 (53)

Bolt

GB5783-87 (M20x55)

Washer

GB93-87 (20)

Bolt

GB5873-86 (M16x30)

Washer

GB93-37 (16)

Gasket

107.11.96.02 (55)

Packing box

107.11.96.03

Gasket

107.11.96.01 (55)

lntermediate rod

107.11.01.02

Water retainer

107.11.70.00

Frame assy

107.11.90.00

Spray pump system

107.11.101.00

Crosshead guidelowar

107.11.90.03

Bolt

107. 1 1. 90. 04-1

Washer

GB97.1-85 (24)

Wire

l13  L=5400

Gasked

107.11.90.26 (Ø40xØ26)

Bolt

107.11.01.01M30

Wire

Ø3  L=2400

Bolt

GB5782-86 (M24x90)

Nut

GB6170-86 (M24)

Spring washer

GB93-87 (24)

Plate

107.11.96.06

Pin

GB119-86 (A10x50)

Single lip oil seal

107.11.97.00

Ring

107.11.96.04

Ring

107.11.96.05

Plate

107..11.96.07

Bolt

GB5783-86 (M10x25)

Washer

GB93-87 (10)

Crosshead guide upper

107.11.90.05

Cover plate

107. 1 1. 90. 08-1

Gasket

107. 11. 90. 09-1

Bolt

GB5783-86 (M16x40)

Washer

GB93-37 (16)

 

 7. On-Site Fault Repair Cases

Case 1: Lubricant Leakage from Oil Box Gasket Failure

Fault Phenomenon: The Lanzhou LS Mud Pump exhibited continuous lubricant leakage from the oil box (107.11.60.00), requiring frequent lubricant replenishment and affecting pump operation. Diagnosis: Disassembly revealed aging and cracking of gasket 107.11.90.33, which had exceeded its service life and lost sealing capability.Repair: Replaced the gasket with an original-matched part, cleaned the oil box sealing surface, and tightened bolts (GB5783-87 M20x55) to 65-70N·m. Result: Leakage ceased, lubricant levels stabilized, and the pump operated normally without further issues.

Case 2: Crosshead Jamming Due to Guide Wear

Fault Phenomenon: The pump experienced abnormal noise, increased vibration, and reduced mud conveying efficiency, with the drive shaft assy (107.11.10.00) failing to rotate smoothly.Diagnosis: Inspection found severe wear on the crosshead guide lower (107.11.90.03), with wear depth exceeding 0.9mm, causing crosshead jamming.Repair: Replaced the crosshead guide, adjusted crosshead clearance to 0.15-0.20mm, and applied ISO VG 68 lubricant to the guide surface. Result: Jamming was resolved, vibration and noise returned to normal, and the pump’s conveying efficiency was fully restored.

Case 3: Fastener Loosening Causing Frame Assy Vibration

Fault Phenomenon: The frame assy (107.11.90.00) displayed excessive vibration during operation, with bolts (GB5873-86 M16x30) loosening repeatedly and posing safety risks. Diagnosis: Washers (GB93-37 16) showed elastic fatigue, failing to provide reliable locking, and bolts were under-tightened during previous maintenance. Repair: Replaced bolts and washers, applied thread lock adhesive, and tightened evenly to 60-65N·m. Result: Frame vibration was eliminated, fasteners remained secure, and pump operation stabilized, reducing safety hazards.

Case 4: Lubrication System Contamination from Oil Seal Damage

Fault Phenomenon: Lubricant turned turbid with metal particles and mud residues, leading to increased wear on the crank shaft assy (107.11.20.00) and potential component failure. Diagnosis: The single lip oil seal (107.11.97.00) was damaged, allowing external dust and mud to enter the lubrication system. Repair: Replaced the oil seal, drained contaminated lubricant, cleaned the entire lubrication system and oil box, and refilled with ISO VG 68 extreme pressure lubricant. Result: Lubricant clarity was restored, crank shaft wear stopped, and component service life was extended, reducing maintenance costs.

8. FAQ

No.

Questions

Answers

1

What lubricant is suitable for the LS Mud Pump’s forced lubrication system (107.11.40.00)?

Use ISO VG 68 extreme pressure industrial gear oil, compliant with GB/T 3141-2019. It resists high temperatures and heavy loads, ensures uniform lubrication of transmission parts, and prevents wear and corrosion. Never mix different types of lubricants, as this can reduce lubrication performance and damage components.

2

How to verify gasket compatibility for the oil box (107.11.60.00)?

Match the gasket’s part number (e.g., 107.11.90.33) and specifications (size, thickness) to the original. Ensure the material is oil-resistant, asbestos-free rubber that can withstand mud and lubricant contact, and check dimensional precision (tolerance ±0.02mm) to avoid leakage.

3

What causes abnormal noise from the crank shaft assy (107.11.20.00) and how to fix it?

Common causes include low or contaminated lubricant, loose fasteners, crosshead guide wear, or bearing damage. First, check and replace lubricant if needed. Tighten loose fasteners and inspect guides/bearings—replace worn components and adjust clearances if noise persists to prevent further damage.

4

What is the recommended replacement cycle for the single lip oil seal (107.11.97.00)?

Replace every 1200 working hours under normal conditions. In dusty, mud-heavy environments, shorten the cycle to 800 working hours. Replace immediately if leakage, lip damage, or loss of elasticity is found to prevent lubricant contamination and internal component wear.

5

What torque should be used for M24 bolts (GB5782-86 M24x90) on the frame assy?

Tighten M24 bolts to 115-125N·m per GB/T 3098.1-2010. Use a calibrated torque wrench to ensure uniform force—over-tightening can deform bolts or damage the frame, while under-tightening leads to loosening and vibration.

9. Procurement Reference & Call to Action

9.1 Procurement Reference Standards

When purchasing 107.11.01.00 series parts for the Lanzhou LS Mud Pump, strictly match original part numbers and specifications to ensure compatibility with the pump’s original configuration. Prioritize parts that comply with GB, JB, and other national/industrial standards, accompanied by formal quality inspection certificates. Verify material compliance (e.g., high-strength steel for structural parts, oil-resistant rubber for seals) and dimensional precision to avoid mismatch-related equipment damage, operational failures, or safety hazards. For lubrication system parts like 107.11.40.00, confirm compatibility with the pump’s lubrication circuit to ensure optimal performance.

9.2 Call to Action

We supply full-series original-matched, high-quality parts for the Lanzhou LS Mud Pump (107.11.01.00 series), covering all components listed—including the forced lubrication system 107.11.40.00 and key transmission parts.We provide professional technical support for procurement selection, fault diagnosis, and maintenance guidance, tailored to your on-site operational needs. Contact us now for detailed quotes and customized sourcing solutions to keep your Lanzhou LS Mud Pump running stably and efficiently.

 

contact us 

Emeil: [email protected]   whatsapp: +86 15275658619