16 Jan 2026

Float Collar & Float Shoe Product Classification

Core Application & Target User Overview

This guide covers professional float collars and float shoes, specifically compatible with casing strings of 127mm, 139.7mm, 177.8mm, 200mm, 244.5mm, and 273mm diameters for oil and gas well cementing operations. Tailored for oilfield service companies, drilling contractors, and exploration enterprises, it addresses the critical demand for high-pressure-resistant, corrosion-resistant, and reliable anti-backflow components to ensure successful cementing and wellbore integrity. All products comply with API 5CT, API 10D, and ISO 14693 standards, undergoing rigorous pressure testing and sealing performance verification to adapt to harsh downhole environments (high temperature, high pressure, and corrosive media).

Float Collar

Float Collar is a key component in oil and gas well cementing, installed above the float shoe to prevent cement slurry backflow and ensure cementing quality. Premature failure (such as seal damage or valve jamming) can lead to cementing failure, wellbore collapse, and costly rework. Our float collars adopt high-strength alloy steel and precision-machined valve structures, featuring excellent pressure-bearing capacity and wear resistance, suitable for vertical, directional, and horizontal well cementing operations.

Field Application Case

A drilling company in the Sichuan Basin encountered cement slurry backflow during 139.7mm casing cementing, resulting in poor cement bond quality. After replacing with our FG ZX QZ series float collar (complying with API 10D), combined with strict installation and pressure testing procedures, the backflow issue was completely resolved. The cement bond log (CBL) showed a qualification rate of 98%, avoiding rework costs of over $150,000.

Serial No.

Product Name & Specification

Material

Main Wear Reasons

Damage Prevention Notes

1

Float Collar FG ZX QZ 127mm

Alloy steel (N80) for body; nitrided steel for valve core; EPDM rubber for sealing ring

1. Seal ring wear from abrasive particles in drilling fluid; 2. Valve core jamming due to cement slurry solidification residue

1. Clean the inner cavity thoroughly before installation to remove drilling fluid residues; 2. Use high-quality drilling fluid with solid particle content ≤2% (per API 10D requirements)

2

Float Collar FG ZX QZ 139.7mm

Alloy steel (N80) for body; nitrided steel for valve core; EPDM rubber for sealing ring

1. Body corrosion from downhole H2S/CO2 corrosive media; 2. Valve seat damage from high-pressure cement slurry impact

1. For sour gas wells, select H2S-resistant material grades (per NACE MR0175); 2. Control cement slurry pumping pressure ≤80% of the float collar's rated pressure

3

Float Collar FG ZX QZ 244.5mm

Alloy steel (L80) for body; nitrided steel for valve core; fluororubber for sealing ring

1. Sealing failure due to high-temperature aging of rubber rings (downhole temperature >150°C); 2. Thread damage during casing running

1. Select high-temperature-resistant fluororubber seals for high-temperature wells; 2. Apply thread compound evenly during installation and control make-up torque per API 5CT

4

Float Collar FG ZX QZ 200mm

Alloy steel (N80) for body; nitrided steel for valve core; EPDM rubber for sealing ring

1. Valve core fatigue failure from frequent backflow pressure impacts; 2. Inner cavity wear from sand-laden drilling fluid

1. Avoid repeated pressure testing and backflow operations; 2. Install sand control filters in the drilling fluid circulation system

5

Float Collar FG ZX QZ 273mm

Alloy steel (L80) for body; nitrided steel for valve core; fluororubber for sealing ring

1. Body deformation from downhole external pressure (deep well >3000m); 2. Seal ring damage from chemical additives in cement slurry

1. Verify the float collar's external pressure rating matches well depth requirements; 2. Test compatibility between cement slurry additives and seal materials before use

6

Float Collar FG ZX QZ 127mm TP-FJ

Alloy steel (N80) for body; nitrided steel for valve core; EPDM rubber for sealing ring

1. TP-FJ component damage from improper installation torque; 2. Seal leakage from foreign matter between the sealing surfaces

1. Use torque wrenches to ensure accurate installation torque; 2. Inspect sealing surfaces for cleanliness and intactness before assembly

7

Float Collar FG ZX QZ 244.5mm BTC

Alloy steel (L80) for body; nitrided steel for valve core; fluororubber for sealing ring; BTC thread with copper plating

1. BTC thread corrosion from downhole moisture; 2. Thread leakage due to insufficient make-up torque

1. Protect threads with anti-corrosion caps during storage and transportation; 2. Follow API 5CT thread make-up procedures and verify torque with a torque gauge

8

Float Collar FG ZX FQ 139.7mm

Alloy steel (N80) for body; nitrided steel for valve core; EPDM rubber for sealing ring

1. Valve core jamming due to cement slurry sedimentation; 2. Seal wear from long-term contact with drilling fluid

1. Ensure cement slurry circulation is sufficient to prevent sedimentation; 2. Replace sealing rings if the float collar is stored for more than 6 months

9

Float Collar FG ZX FQ 177.8mm

Alloy steel (N80) for body; nitrided steel for valve core; EPDM rubber for sealing ring

1. Body wear from casing string vibration during running; 2. Valve seat erosion from high-velocity cement slurry

1. Install centralizers to reduce casing vibration; 2. Control cement slurry pumping rate within the recommended range (≤1.2 m³/min)

10

Float Collar FG ZX FQ 273mm

Alloy steel (L80) for body; nitrided steel for valve core; fluororubber for sealing ring

1. Sealing failure from high-pressure cyclic loading; 2. Valve core damage from foreign objects (e.g., casing debris) entering the cavity

1. Conduct pressure cycling tests before downhole use (per API 10D); 2. Clean the casing string thoroughly to remove debris before installing the float collar

Float Collar & Float Shoe Combination

Float Collar & Float Shoe Combination is an integrated solution for well cementing, combining the anti-backflow function of the float collar and the guiding/anti-backflow function of the float shoe. It simplifies installation, improves operational efficiency, and ensures consistent cementing quality. Our combinations adopt matched precision components and high-strength materials, with excellent synergy and reliability, suitable for complex well conditions such as deep wells and horizontal wells.

Serial No.

Product Name & Specification

Material

Main Wear Reasons

Damage Prevention Notes

1

Float Collar Float Shoe FXFG FZ ZS 139.7mm

Alloy steel (N80) for body; nitrided steel for valve core; EPDM rubber for sealing ring; wear-resistant alloy for float shoe guide head

1. Float shoe guide head wear from contact with wellbore rock formations; 2. Seal leakage between float collar and float shoe connection

1. Inspect wellbore for irregularities before casing running; 2. Ensure tight connection between float collar and float shoe and apply thread sealant

2

Float Collar Float Shoe FXFG FZ FQ 273mm

Alloy steel (L80) for body; nitrided steel for valve core; fluororubber for sealing ring; wear-resistant alloy for float shoe guide head

1. Valve core jamming in both components due to cement slurry solidification; 2. Body corrosion from downhole corrosive media

1. Complete cementing operations within the cement slurry setting time; 2. Select corrosion-resistant materials for sour gas wells (complying with NACE MR0175)

3

Float Collar Float Shoe FXFG FZ QZ 139.7mm

Alloy steel (N80) for body; nitrided steel for valve core; EPDM rubber for sealing ring; wear-resistant alloy for float shoe guide head

1. Float shoe guide head damage from impact with wellbore obstacles; 2. Seal ring aging from high downhole temperature

1. Use a casing shoe guide during running to avoid impact; 2. Select high-temperature-resistant seals for wells with downhole temperature >120°C

4

Float Collar Float Shoe FXFG FZ QZ 177.8mm

Alloy steel (N80) for body; nitrided steel for valve core; EPDM rubber for sealing ring; wear-resistant alloy for float shoe guide head

1. Connection thread damage during casing running; 2. Valve seat erosion from high-velocity drilling fluid

1. Handle with care during transportation and installation to avoid thread collision; 2. Control drilling fluid circulation velocity ≤1.5 m/s

Procurement Guidelines & Technical Support

Selecting the right float collar and float shoe is crucial to ensuring the success of oil and gas well cementing operations and the long-term integrity of the wellbore. Our products fully comply with API 5CT, API 10D, and ISO 14693 standards, with complete quality certification, pressure testing reports, and material traceability documents. We provide professional technical support, including product selection based on well depth, temperature, pressure, and well type, on-site installation guidance, and post-sales technical consultation. Whether you need standard specifications or customized solutions for complex well conditions, our team is committed to delivering high-quality products and reliable services. Contact us today to discuss your specific requirements and get tailored cementing component solutions.

 

contact us 

Emeil: [email protected]   whatsapp: +86 15275658619

Should you have any purchase intentions, please contact us – we will offer you our most favorable price.


Prosperity Petroleum Equipment

Quick Inquiry