We focus on the production and supply of high-precision, durable industrial equipment parts, covering a wide range of components specifically designed for oil drilling rigs, top drives, industrial boilers, hydraulic systems, and monitoring equipment. Our product portfolio includes key parts such as the ignition module CD200 791070-12, oil field monitoring system FBZJYP-4-5, ZJ30 hydraulic control valve 4WH6D50B, and ZJ50 floating platform 180.03.02—all engineered to address the critical challenges of industrial operations. Designed with strict adherence to international industrial standards (ISO 9001:2015, API 6A for oil and gas equipment), our parts prioritize compatibility, durability, and performance to minimize equipment downtime, reduce maintenance costs, and ensure safe, efficient operation. This document serves as a comprehensive reference for procurement decisions and technical support, featuring detailed product information, practical maintenance guidelines, real-world fault solutions, and clear procurement guidance—all tailored to meet the needs of industrial users.
Core Purpose & Target User Needs
Our industrial parts are precisely adapted to key equipment models, including ZJ30, ZJ50, ZJ70D oil drilling rigs, top drives, boiler KDB-250FA, electromagnetic brake cabinets, and oil field monitoring systems. Target users include procurement managers, equipment maintenance technicians, engineering teams, and on-site operators in industries such as oil and gas drilling, thermal power generation, heavy machinery, and industrial manufacturing. These users frequently face frustrating pain points: unplanned equipment downtime due to incompatible or low-quality replacement parts, high maintenance costs from short-lived components, difficulty sourcing parts with clear technical specifications, and delays in fault resolution that impact productivity. Our core purpose is to provide cost-effective, OEM-standard parts that ensure seamless compatibility with existing equipment, reduce unplanned downtime by 38% on average, cut maintenance costs by 30%, and deliver reliable performance in harsh industrial environments—ultimately helping users maintain stable operations and maximize productivity.
Product Introduction
Key Product Range & Specifications
Our product line covers ignition systems, monitoring equipment, hydraulic components, seals, filters, valves, and more, all manufactured with rigorous quality control to meet industrial-grade standards. Key products include:
• Ignition Module CD200 791070-12: A high-reliability ignition control component with an operating voltage of 12V DC, ignition energy of ≥ 80mJ, and operating temperature range of -40°C to 85°C, designed for industrial engines and combustion systems, ensuring stable ignition and efficient fuel combustion.
• Oil Field Monitoring System FBZJYP-4-5: A four-picture control monitoring system with real-time data transmission accuracy of ±1%, supporting 4-channel monitoring and 5-inch display, suitable for oil field wellsite monitoring, enabling remote observation of equipment operation status and early fault warning.
• ZJ Series Components: Including ZJ30 hydraulic control valve 4WH6D50B (rated pressure 31.5MPa, flow rate 100L/min), ZJ30 air compressor drive shaft and belt 4N-8221, ZJ50 floating platform 180.03.02, and ZJ70D 4” threaded union FIG1003—all tailored for ZJ series oil drilling rigs, ensuring reliable power transmission and system stability.
• Seals & Gaskets: Such as O-RING S01-1173-01N (8 1/2 X 8 11/16 X 3/32) for top drives, front seal RJ11148.09.11.02, and ZJ50 sealing ring PSZ75 BA8007, made of high-quality fluororubber and nitrile rubber, with high temperature resistance (up to 200°C) and oil resistance, preventing leakage and extending equipment life.
• Other Key Components: Air filters 1318821/1318822, quick coupler DQ70BSC 5126050050, rubber impellers F6147R55/D3147R55, valve island 512701010000330004, and bearing 3519—all engineered to meet the specific operational requirements of industrial equipment, with strict adherence to dimensional and performance standards.
Function Description
Core Functions of Key Products
Each product is designed with targeted functions to solve specific industrial challenges, ensuring optimal equipment performance and operational safety:
• Ignition Module CD200 791070-12: Converts low-voltage electrical signals into high-voltage ignition energy to ignite fuel in industrial engines or combustion systems, with overcurrent and overheating protection functions, ensuring stable ignition even in harsh environments (dust, vibration, extreme temperatures).
• Oil Field Monitoring System FBZJYP-4-5: Collects, processes, and displays real-time data from oil field equipment (e.g., pressure, temperature, flow rate) through four monitoring channels, supporting data storage and fault alarm functions, helping operators detect potential issues early and avoid major equipment failures.
• Hydraulic Control Valve 4WH6D50B (ZJ30DB): Controls the flow direction and pressure of hydraulic oil in ZJ30 drilling rig hydraulic systems, enabling precise operation of hydraulic actuators (cylinders, motors), with a response time of ≤ 0.1s, ensuring smooth and efficient equipment operation.
• Seals & O-Rings (S01-1173-01N, PSZ75 BA8007): Create a tight seal between equipment components, preventing leakage of hydraulic oil, gas, or other media, maintaining system pressure stability, and resisting wear, corrosion, and high temperatures—critical for the reliability of hydraulic and pneumatic systems.
• Air Filters 1318821/1318822: Filter dust, debris, and other impurities from the air entering industrial equipment (e.g., air compressors, engines), with a filtration efficiency of ≥ 99.5%, protecting internal components from wear and extending equipment service life.
Structural Features
Design Advantages for Durability & Compatibility
Our products adopt advanced structural designs and high-quality materials to ensure durability, seamless compatibility, and easy installation and maintenance, addressing the practical needs of on-site operations:
• Ignition Module CD200 791070-12: Adopts a sealed aluminum alloy housing for anti-corrosion and anti-vibration protection (IP65 rating), with an integrated heat dissipation structure that reduces operating temperature by 15°C, extending the module’s service life; the plug-and-play design allows for quick replacement without professional tools.
• FBZJYP-4-5 Monitoring System: Features a rugged, waterproof housing (IP67 rating) suitable for outdoor oil field use, with a high-brightness LCD display that is clearly visible in direct sunlight; the modular design allows for easy maintenance and expansion of monitoring channels.
• ZJ30 Hydraulic Control Valve 4WH6D50B: Adopts a spool valve structure with precision machining (tolerance ≤ 0.005mm), ensuring smooth operation and low leakage (≤ 0.1L/min); the valve body is made of high-strength cast steel, withstanding high pressure and impact loads in drilling rig operations.
• Top Drive O-RING S01-1173-01N: Features a circular cross-section with a precision-machined surface (surface roughness ≤ 0.8μm), ensuring tight sealing even under high pressure (up to 40MPa); the fluororubber material provides excellent resistance to oil, high temperature, and chemical media.
• Air Filters 1318821/1318822: Adopt a multi-layer filtration structure (primary filter + fine filter), with a large filter area (≥ 0.5m²) to reduce pressure loss (≤ 0.02MPa) and extend filter service life; the quick-release cover allows for easy filter element replacement.
Applicable Working Conditions
All our products undergo rigorous environmental and performance testing to ensure reliable operation in the harsh, complex working conditions of industrial sites:
• Temperature Range: -40°C to 220°C (for high-temperature resistant seals and ignition modules), suitable for both cold northern oil fields and high-temperature boiler rooms.
• Pressure Range: 0-50MPa (for hydraulic control valves, pressure sensors, and sealing rings), meeting the high-pressure requirements of oil drilling rigs and hydraulic systems.
• Environmental Resistance: IP65-IP67 protection rating (for monitoring systems, ignition modules, and quick couplers), dustproof, waterproof, and anti-vibration (≤ 15g), suitable for outdoor oil fields, construction sites, and mining operations.
• Corrosion Resistance: 316L stainless steel, fluororubber, and anti-corrosion coatings are used to resist acid, alkali, and oil corrosion, making our parts suitable for offshore oil platforms, chemical plants, and other corrosive environments.
• Load Capacity: ZJ30 air compressor drive shafts can transmit torque up to 2500N·m, hydraulic control valves can handle flow rates up to 100L/min, and friction discs W14-07-900 can withstand load pressures up to 30MPa—meeting the high-load requirements of heavy industrial equipment.
Maintenance & Care Recommendations
Proper maintenance is key to extending the service life of our products, reducing maintenance costs, and ensuring consistent performance. Below are practical, easy-to-follow maintenance guidelines for key products, designed for on-site technicians:
• Ignition Module CD200 791070-12: Inspect the module’s wiring connections every 2 months to ensure they are tight and free of corrosion; clean the heat dissipation surface with a dry cloth to prevent overheating; replace the module if it fails to ignite or shows signs of overheating (e.g., discoloration).
• FBZJYP-4-5 Monitoring System: Calibrate the monitoring sensors every 6 months using standard calibration tools to ensure data accuracy (error ≤ ±1%); clean the display screen and housing with a damp cloth to remove dust and debris; check the power supply and data cables regularly for damage.
• Hydraulic Control Valve 4WH6D50B: Replace the hydraulic oil every 12 months (or 2000 working hours) and clean the valve core to prevent clogging by impurities; add lubricating oil (ISO VG 46) to the valve stem every 3 months to reduce friction; check for oil leakage and tighten connections as needed.
• Seals & O-Rings: Replace seals every 12-18 months (or when leakage is detected); ensure the sealing surface is clean and free of scratches before installation; avoid using sharp tools to install seals, as this can damage the rubber and cause leakage.
• Air Filters 1318821/1318822: Replace the filter element every 3 months (or when the pressure difference exceeds 0.05MPa); clean the filter housing regularly to remove accumulated dust; ensure the filter is properly sealed after replacement to prevent unfiltered air from entering the equipment.
Note: All maintenance operations should be performed by trained professional technicians in accordance with the equipment’s operation manual to avoid safety risks and equipment damage. Always use genuine replacement parts to ensure compatibility and performance.
We supply the following spare parts:
ignition module CD200 791070-12 |
connection flange QGL.01.LF2.T30 20hole |
O-RING, 8 1/2 X 8 11/16 X 3/32 FOR TOP D RIVE PT.NO:S01-1173-01N |
Monitoring system for oil field FBZJYP-4-5Four picture control |
air filter 1318821/1318822 |
quick coupler DQ70BSC 5126050050 |
Compressor drive shaft ZJ-30 air compressor belt 4N-8221 |
Hydraulic control valve\ZJ30DB 4WH6D50B |
Inclinometer YST-48R Pressure sensor YL-5 3908001 MWD |
Weight watch JZ sensitive dial 150.250.400.500 type |
mandrel BKD-7-6D11 |
floating platform\ZJ50 180.03.02 |
Control circuit board PC2 board for electromagnetic brake cabinet |
Rubber Impeller: F6147R55 D3147R55 |
Valve Island 512701010000330004 |
End cap gasket P6900068AA |
retaining ring P1100344AA |
Accelerator 351311 SN 190107-500089 CATC27 |
Freezing Point Meter WZ-403 |
Clamp frame press oil filling cup |
Pneumatic control valve VL/0-3-1/8-B |
Front seal RJ11148.09.11.02 |
23444-01-72 Seal shaft sleeve |
226469breathing valve |
Threaded union\ZJ70D 4” FIG1003 |
Touring car hook YG180 Hook support pin YG180-11 |
Governor assembly 2W7325 |
push ringG8029HS1A05 |
Flange type double scale seismic pressure gauge |
Friction disc W14-07-900 |
Gear hub 515912 |
Weight table ZJ movement assembly JZ250 |
WEAR PLATE; Part Number: 36001-0516A |
Friction copper plate W36-11-301 |
big spring P9000134AA |
Bolt AH33001-0515A |
foot valve IA484copper thrust pad 6883492 |
Surface BOP Control Kit Repair Kit FKQ4005B |
Boiler KDB-250FA exhaust pipe (chimney assembly) KDJ-VS |
Power screw 000245*0069 |
Explosion-proof master controller 330302050003000000 |
High pressure control valve conversion flange BX155*BX152 |
ball valveG1/2″ 4600300001 |
stud T500-6007 |
6834679Intake valve 1152368 |
middle water jacket W36-11-303 |
BAsealing ring ZJ50 PSZ75 BA8007 |
Oil filter 12V4000(5241800310)Foot Control Throttle Valve P50208-LH-1 |
Adapter\ZJ50 Ф1270 L=960 |
Bearing 3519 |
On-Site Fault Maintenance Cases
Below are 3 real on-site fault cases, featuring practical solutions to help you quickly resolve common issues with our products, minimizing downtime and reducing maintenance costs:
Case 1: Ignition Module CD200 791070-12 Failure
Fault Phenomenon: An industrial engine failed to start, and the ignition system showed no spark. Inspection: After checking, the ignition module CD200 791070-12 was found to have a damaged internal circuit due to overheating, caused by a blocked heat dissipation surface. Solution: Replace the ignition module with a new CD200 791070-12, clean the installation area to ensure proper heat dissipation, and check the wiring connections to ensure they are tight. Result: The engine started normally, and the ignition system operated stably; no further failures occurred within 8 months.
Case 2: FBZJYP-4-5 Monitoring System Data Inaccuracy
Fault Phenomenon: An oil field wellsite FBZJYP-4-5 monitoring system displayed inaccurate pressure data, with a deviation of more than 3% from the actual pressure. Inspection: The monitoring sensors were not calibrated for over 1 year, and the sensor probes were contaminated with oil and debris. Solution: Clean the sensor probes with a neutral cleaning agent, calibrate the sensors using a standard pressure gauge, and reset the monitoring system. Result: The data accuracy was restored to ±1%, and the system provided reliable real-time monitoring of wellsite conditions.
Case 3: ZJ30 Hydraulic Control Valve 4WH6D50B Leakage
Fault Phenomenon: A ZJ30 drilling rig hydraulic control valve 4WH6D50B had severe oil leakage, causing a drop in system pressure and affecting rig operation. Inspection: The valve core seal was worn and damaged, and the valve body had accumulated impurities. Solution: Disassemble the valve, clean the valve body and core, replace the worn seal with a new one, and reassemble the valve. Result: The oil leakage stopped, system pressure was restored to normal, and the hydraulic system operated smoothly.
FAQ (Frequently Asked Questions)
Question | Answer |
Is the O-RING S01-1173-01N compatible with all top drive models? | The O-RING S01-1173-01N (8 1/2 X 8 11/16 X 3/32) is specifically designed for top drive systems, and it is compatible with most standard top drive models used in oil drilling operations. If you have a specific top drive model, please provide the model number, and we can confirm compatibility to ensure a perfect fit. |
What is the service life of the FBZJYP-4-5 oil field monitoring system under normal working conditions? | Under normal working conditions (outdoor oil field environment, regular maintenance, and calibration), the FBZJYP-4-5 monitoring system has a service life of ≥ 6 years. The sensors have a service life of 3-4 years, and we provide replacement sensors to extend the system’s overall service life. |
Do you provide technical support for the installation and maintenance of ZJ30 hydraulic control valve 4WH6D50B? | Yes, we provide comprehensive technical support for all our products, including the ZJ30 hydraulic control valve 4WH6D50B. Our team of professional engineers can provide on-site installation guidance, maintenance training, and fault diagnosis services to help you resolve any technical issues quickly and efficiently. |
Procurement Guide & Technical Support
We are committed to providing high-quality industrial parts that meet or exceed OEM standards, with strict quality control throughout the production process. Each part undergoes three rounds of rigorous testing—raw material inspection, production process inspection, and final performance testing—to ensure a qualification rate of ≥ 99.9%. Our products are cost-effective, with prices 12-25% lower than original OEM parts, while maintaining the same level of durability, compatibility, and performance.
If you need to purchase any of the products mentioned (including ignition module CD200 791070-12, monitoring system FBZJYP-4-5, ZJ30 hydraulic control valve 4WH6D50B, and other components), please provide the part number, equipment model, and required quantity. We will promptly provide you with a detailed quotation, product technical specifications, and quality certification documents. In addition to product supply, we offer professional technical support, including on-site fault diagnosis, maintenance guidance, and replacement part supply, to ensure your equipment operates stably and efficiently.
Choose our industrial parts to minimize equipment downtime, reduce maintenance costs, and ensure the safe and efficient operation of your industrial equipment. We are dedicated to providing reliable products and comprehensive solutions to support your business development, and we look forward to serving your procurement and technical needs.
contact us :
Emeil: [email protected] whatsapp: +86 15275658619