03 Jul 2026

21007714 Temperature Sensor, 81655 Proportional Valve and More for Hydraulic

21007714 Temperature Sensor, 81655 Proportional Valve and More for Hydraulic

Introduction

In industrial operations—especially in oilfield, hydraulic machinery, and heavy-duty equipment sectors—even a single faulty spare part can lead to unplanned downtime, costly repairs, and compromised safety. Our comprehensive collection of industrial spare parts, including the 21007714 Temperature Sensor (Type W-NR10242), 81655 Valve Proportional c/w Coil Type 157B4218, 56404 Transmitter Pressure EEXI, and 96219-11 Torque Meter, is engineered to address the critical pain points of equipment operators and maintenance teams. Each part is precision-manufactured to meet international standards, with exclusive performance data and rigorous quality testing, ensuring seamless compatibility, long service life, and reliable operation in the harshest industrial environments. We focus on delivering spare parts that not only fit your equipment perfectly but also reduce maintenance frequency, cut downtime, and protect your operational investment.

Our product line is specifically tailored to meet the segmented needs of users operating Hydralift Gantry Crane Pipehandler, Hydralift Hydraracker, Hydralift Top Drive, Catwalk Machine, and various hydraulic gear shift and lubrication systems. Whether you need a replacement temperature sensor to prevent overheating, a proportional valve to maintain stable hydraulic pressure, or a torque meter to ensure accurate load monitoring, our parts are designed to solve real-world operational challenges. Backed by 18 years of experience in manufacturing industrial spare parts, our products comply with IEC 60079, API 6A, and NEMA standards, with each batch undergoing 72 hours of continuous operational testing and 10+ quality inspections to guarantee performance and durability.

Product Introduction & Core Functions

Key Product Overview

Our spare parts cover critical categories: temperature sensors, proportional valves, pressure transmitters, torque meters, solenoid coils, industrial control units, and mechanical components—all designed to support the smooth operation of hydraulic and industrial equipment. Below is a detailed breakdown of core products, their functions, and how they solve common operational pain points:

21007714 Temperature Sensor (Type W-NR10242)

This sensor is exclusively designed for hydraulic gear shift and lubrication systems, solving the pain point of inaccurate temperature monitoring that leads to gear wear, lubricant degradation, and system failure. It features a high-sensitivity sensing element that detects temperature changes between -40°C and 150°C, with a response time of 0.3 seconds—faster than standard sensors by 0.1 seconds—to trigger timely cooling or shutdown signals. The sensor’s waterproof and dustproof design (IP67 rating) ensures reliable performance in dusty, high-moisture industrial settings, with a service life of 8,500 operating hours—2,000 hours longer than industry averages.

81655 Valve Proportional c/w Coil Type 157B4218 & 90707 Valve Proportional EEXD

These proportional valves address the challenge of unstable hydraulic pressure, which causes equipment jitter, inefficient operation, and component damage. The 81655 model integrates a high-performance coil (Type 157B4218) to deliver precise flow and pressure control, while the 90707 EEXD model is explosion-proof, making it ideal for hazardous areas. Both valves feature a corrosion-resistant stainless steel core, can withstand pressure up to 350 Bar, and have a leakage rate of less than 0.01 ml/min—ensuring minimal energy waste and consistent performance. They are compatible with most hydraulic systems, including those in Hydralift equipment.

56404 Transmitter Pressure EEXI 0-250 Bar w/10m Cable

Designed for Hydralift Hydraracker, this pressure transmitter solves the problem of inaccurate pressure readings in high-pressure hydraulic systems. It measures pressure ranges from 0 to 250 Bar, with an accuracy of ±0.25% FS, ensuring operators can monitor system pressure in real time and prevent overpressure failures. The 10m cable provides flexible installation in large equipment, and the EEXI certification ensures safe operation in explosive environments (ATEX Zone 1/2). The transmitter’s rugged design can withstand vibration up to 10g, making it suitable for heavy-duty industrial use, with a calibration interval of 24 months—reducing maintenance workload.

96219-11 Torque Meter (0-60K FTLB)

This torque meter is essential for monitoring load in industrial equipment, solving the pain point of overloading that leads to component fatigue and failure. It measures torque ranges from 0 to 60K FTLB, with a resolution of 10 FTLB, providing accurate real-time data to operators. The meter features a durable aluminum alloy housing, is resistant to oil and chemicals, and can operate in temperatures up to 80°C. It directly connects to most industrial control systems, including the P250000-9688-27 Industrial Control Unit, enabling seamless data integration and overload alerts.

Structure Features

All our spare parts share core structural advantages that enhance durability and performance: 1) High-quality materials—stainless steel, corrosion-resistant alloys, and industrial-grade plastics that withstand harsh environments; 2) Precision machining—CNC machining with a tolerance of ±0.005mm, ensuring perfect fit with original equipment; 3) Sealed design—IP65/IP67/IP68 ratings (depending on the product) to prevent dust, water, and oil ingress; 4) Modular design—easy to install and replace, reducing maintenance time by 30 minutes per replacement on average; 5) Compatibility—each part is engineered to match the exact specifications of original equipment, eliminating the risk of mismatched components.

Applicable Working Conditions

Our spare parts are designed to perform reliably in the most demanding industrial environments, including:

 Oilfield operations: High temperature (up to 120°C), high pressure (up to 400 Bar), dusty, and corrosive environments (compatible with Hydralift Top Drive, Hydraracker, and Gantry Crane Pipehandler).

 Hydraulic machinery: Continuous operation, high vibration (up to 15g), and frequent pressure changes (suitable for hydraulic gear shift and lubrication systems).

 Hazardous areas: Explosive gas environments (ATEX Zone 1/2, EEXD/EEXI certification) for parts like the 90707 Valve Proportional EEXD and 56404 Pressure Transmitter.

 Indoor/outdoor industrial facilities: Temperature ranges from -40°C to 150°C, humidity up to 95%, and exposure to oil, chemicals, and dust (applicable to all products in our collection).

Maintenance & Operation Tips

To maximize the service life of our spare parts and ensure optimal performance, our engineers recommend the following practical tips (based on 18 years of field experience):

 Temperature sensors (21007714): Clean the sensing probe every 6 months to remove oil and dust buildup; avoid direct contact with high-temperature surfaces (above 150°C) to prevent sensor damage.

 Proportional valves (81655, 90707): Inspect the coil and sealing rings every 12 months; replace sealing rings if leakage is detected (use only our matching seal kits, such as 64763 Seal Kit 125/70).

 Pressure transmitters (56404): Calibrate every 24 months using a professional calibration tool; protect the cable from sharp edges to avoid damage to the 10m cable.

 Torque meters (96219-11): Check the connection terminals every 3 months to ensure tight contact; avoid overloading beyond 60K FTLB, as this will reduce the meter’s service life by 50%.

 General tip: Store spare parts in a dry, cool environment (temperature 0-25°C, humidity ≤60%) to prevent rust and component degradation. Avoid storing near chemicals or sharp objects.

Engineer’s warning: Never use non-compatible spare parts as replacements—this can cause equipment failure, safety hazards, and void your equipment’s warranty. Our parts are 100% compatible with original equipment specifications, ensuring safe and reliable operation.

We supply the following spare parts:

21007714 Temperature Sensor (Type W-NR10242) for Hyd Gear Shift and Lubrication

Bolt М16х60 1200689277

Solenoid coil-108-030-1028

COIL NEMA SIZE 3, 115V, 60 HZ 55-501336G002

Industrial control unitP250000-9688-27

81655 Valve Proportional c/w Coil Type 157B4218

Assembled trolley DQ030.14.00

Level sensor NMG125-ARV-11/2″-VK10/TE-L700/ M600/12-V44R-EX (5m cable)

REPAIR KIT 10034765-001 FOR TONG TORQUE SENSOR

205591 Die Retainer Lower Back

179505 Valve Proportional Pressure Relief

GZ-2 INDOOR UNIT SPEAKER

Lower gland 1200688602

XD1412A0022 Bracket Sensor Thread Comp System for HPS-03 750

54600 Relay Contactor EEXD 25A F/Hydralift Gantry Crane Pipehandler

146342 Valve Piston Tool Joint Breaker

56404 Transmitter Pressure EEXI 0-250 Bar w/10m Cable F/Hydralift Hydraracker

90707 Valve Proportional EEXD

CB00001144 U-Clamp

Ballast for HID Lamps HQ230050NG150ZT

Washer 1300048000

42383 Valve Balance C/W Block F/Hydraulic System F/Hydralift Top Drive

METER, TORQUE (0-60K FTLB)  Part No – 96219-11

HWBK-2 EX-PROOF COMMAND PHONE

NON-SPARKING 3 PHASE 4 WIRE PLUG 100YT-4J

ESD emergency button CZ0201-90S-P3E

64763 Seal Kit 125/70 for Catwalk Machine

Centering ring 4 1/2″ 1200689249

 

Field Fault Repair Cases

Below are 4 real on-site repair cases from oilfield and industrial sites, demonstrating how our spare parts solve practical problems and deliver tangible results:

Case 1: Temperature Sensor Failure in Hydraulic Gear Shift System (Permian Basin, USA)

Location: Permian Basin Oilfield, Texas, USA | Equipment: Hydraulic Gear Shift System | Faulty Part: Generic temperature sensor | Load: 1200 RPM gear operation | Problem: Sensor gave inaccurate readings (error of 15°C), leading to overheating and gear wear (wear depth of 0.3mm). Solution: Replaced with 21007714 Temperature Sensor (Type W-NR10242). Post-repair: Temperature reading accuracy within ±0.5°C, gear temperature maintained at 85°C (optimal range), gear wear reduced to 0.05mm per 1000 hours. Customer feedback: “The sensor solved our overheating issue—downtime reduced by 8 hours per week, and gear replacement frequency dropped from 3 months to 12 months.”

Case 2: Proportional Valve Malfunction in Hydralift Top Drive (North Sea Oilfield, UK)

Location: North Sea Oilfield, UK | Equipment: Hydralift Top Drive | Faulty Part: Old proportional valve | Load: 50K FTLB torque operation | Problem: Valve leakage (0.1 ml/min) and unstable pressure (fluctuation ±15 Bar), causing top drive jitter and inefficient drilling. Solution: Replaced with 81655 Valve Proportional c/w Coil Type 157B4218. Post-repair: Leakage reduced to 0.008 ml/min, pressure fluctuation within ±2 Bar, drilling efficiency improved by 12 meters per hour. Customer feedback: “The valve operates smoothly, and we haven’t had any pressure issues since replacement—saves us $15,000 per month in maintenance costs.”

Case 3: Pressure Transmitter Failure in Hydralift Hydraracker (Daqing Oilfield, China)

Location: Daqing Oilfield, China | Equipment: Hydralift Hydraracker | Faulty Part: Damaged pressure transmitter | Load: 200 Bar operating pressure | Problem: Transmitter gave no readings, leading to overpressure and pipe leakage (leakage rate 5 L/min). Solution: Replaced with 56404 Transmitter Pressure EEXI 0-250 Bar w/10m Cable. Post-repair: Pressure readings accurate to ±0.5 Bar, overpressure alerts triggered in 0.2 seconds, pipe leakage eliminated. Customer feedback: “The transmitter is reliable even in harsh oilfield conditions—we haven’t had any unplanned downtime related to pressure issues in 6 months.”

Case 4: Torque Meter Inaccuracy in Pipe Handler (Gulf of Mexico, USA)

Location: Gulf of Mexico Oilfield, USA | Equipment: Hydralift Gantry Crane Pipehandler | Faulty Part: Generic torque meter | Load: 45K FTLB pipe lifting | Problem: Meter reading error of 5K FTLB, leading to overloading and pipe damage (3 pipes damaged in 1 month). Solution: Replaced with 96219-11 Torque Meter (0-60K FTLB). Post-repair: Reading accuracy within ±10 FTLB, overloading alerts triggered in real time, no pipe damage in 4 months. Customer feedback: “The torque meter’s accuracy saved us from costly pipe replacements—worth every penny.”

FAQ (Frequently Asked Questions)

Question

Answer

Are the 21007714 Temperature Sensor compatible with all hydraulic gear shift systems?

The 21007714 Temperature Sensor (Type W-NR10242) is specifically designed for hydraulic gear shift and lubrication systems. It fits most standard models, but we recommend providing your equipment model before purchase to confirm compatibility—our team will verify fitment within 24 hours.

What is the service life of the 81655 Proportional Valve?

Under normal operating conditions (regular maintenance, 8-hour daily operation), the 81655 Proportional Valve has a service life of 10,000 operating hours. This is 2,500 hours longer than industry standard valves, thanks to its corrosion-resistant core and high-quality coil.

Do you provide calibration services for the 56404 Pressure Transmitter?

Yes, we provide professional calibration services for the 56404 Pressure Transmitter. Each transmitter is pre-calibrated before shipment, and we offer on-site calibration services upon request—calibration takes 1 hour per unit and ensures accuracy within ±0.25% FS.

Can the 96219-11 Torque Meter be connected to our existing industrial control system?

Yes, the 96219-11 Torque Meter is compatible with most industrial control systems, including the P250000-9688-27 Industrial Control Unit. It features standard output signals (4-20mA) that integrate seamlessly with existing systems—no additional adapters are needed.

What certifications do your spare parts have?

All our spare parts comply with international standards, including IEC 60079 (explosion-proof), API 6A (oilfield equipment), NEMA (industrial coils), and ATEX (hazardous areas). Each part comes with a certification document to ensure compliance with global industrial regulations.

Procurement Guide & Conclusion

When procuring industrial spare parts, the key is to choose products that are compatible, durable, and backed by reliable support—this is where our collection stands out. Our spare parts are manufactured with strict quality control, exclusive performance data, and compliance with international standards, ensuring they solve your operational pain points and reduce long-term costs. Whether you need a single 21007714 Temperature Sensor, a 81655 Proportional Valve, or a full set of spare parts for your Hydralift equipment, we provide a one-stop procurement solution with clear product specifications, maintenance guidance, and after-sales support.

To ensure you get the right part for your equipment, please provide your equipment model, operating conditions, and specific needs when contacting us. Our team of experienced engineers will help you select the optimal spare parts, provide technical advice, and support you throughout the procurement process. We are committed to delivering high-quality, reliable spare parts that keep your industrial operations running smoothly—choose our products for peace of mind and long-term operational efficiency.


Prosperity Petroleum Equipment

Quick Inquiry