17 Sep 2026

ZKYZ-630II Electric Hydraulic Control Parts, FYS0 BOP Handling Components

1. Core Application Orientation & Segmented User Demand

1.1 Core Usage & Matched Host Equipment Model

This integrated batch of ZKYZ-630I/630II explosion-proof electric control assemblies, BY series hydraulic power components, FYS0 BOP hoisting accessories, hydraulic valve control units and standardized filtration connection fittings is custom machined for ZKYZ-630II main explosion-proof electric hydraulic control cabinet, fully compatible with 604-1114 J2K-160 cycloid motor hydraulic system and FYS0 series onshore BOP handling hoisting equipment. All components comply with API 16A BOP handling machinery standard, ATEX Ex d IIB T4 explosion-proof electrical certification, ISO 4401 hydraulic valve installation specification and GB/T 276 rolling bearing industry standard. Fabrication and assembly workshops hold ISO 9001 electromechanical full lifecycle quality certification and SGS hydraulic impact endurance testing qualification, supplying traceable OEM interchange spare parts for round-the-clock explosion-prone oilfield BOP lifting, clamping and hydraulic cyclic operation. Target segmented users cover explosive-class onshore drilling site maintenance teams, oilfield BOP system centralized procurement departments, explosion-proof electric cabinet overhaul contractors, hydraulic loop debugging specialists and regional high-risk zone rig spare part stocking suppliers. Core segmented user demands include explosion-proof grade matched plug-and-play replacement, stable star-delta motor soft startup, multi-valve coordinated hydraulic pressure regulation, real-time liquid level temperature linkage monitoring, and one-stop component sourcing to fix BOP cable traction jitter, hydraulic system pressure runaway, explosion-proof circuit false tripping, filter blockage oil starvation and electric signal disconnection common high-risk onsite faults.

1.2 Pre-positioned BOP Operation Field Pain Points Solved

 Generic aftermarket star delta starters generate starting current surge exceeding 58A under 240kN BOP lifting load, burning low-voltage contactors in ZKYZ-630II explosion-proof electric cabinet

 Ordinary overflow and relief valves fail graded pressure unloading, causing J2K-160 cycloid hydraulic system pressure surge up to 33MPa, damaging gear pump internal mating parts

 Common non-explosion-proof electrical components suffer dust and hydrocarbon gas erosion, triggering intermittent circuit disconnection in Zone1 oilfield hazardous operation areas

 Universal filter elements have low dirt holding capacity, blocking oil suction loop within 320 working hours and leading to BYT201 oil pump motor oil starvation heating fault

2. Standardized Full Product Technical Introduction

2.1 Complete Product Portfolio Overview

This spare part set covers seven core functional categories: ZKYZ-630II series explosion-proof electric control modules including star delta starter, multi-spec AC contactors, thermal relays, explosion-proof heater and power supply units; ZKYZ-630 matched filtration parts covering dual oil suction filters, dedicated filter elements and dual-style air filters; DB series hydraulic valves, compensation valve, check valve and ZKYZ-630II.09.01B valve block hydraulic regulation assemblies; BY series oil pump motor, cooler assembly, coupling and variable pump hydraulic power components; FYS0 copper bushing pulley, φ28 lifting cable dedicated BOP handling structural parts; explosion-proof sensor, liquid level gauge, liquid level thermometer and electrical connector signal transmission parts; circuit breaker, fuse cores, pipe brackets, tee joints and standard bearings installation fastening accessories. High-frequency searched procurement models include ZKYZ-630II-W2600 star delta starter, DB10-2-30/315 overflow valve, FYS0-09.02 φ28 lift cable and TF-400X180F-Y oil suction filter. Exclusive third-party hazardous oilfield lab verified data: this OEM explosion-proof component set extends BOP hydraulic-electric integrated overhaul cycle by 1240 working hours, and reduces hazardous zone electrical fault troubleshooting time by 8 working hours bimonthly compared with modified general industrial spare parts.

2.2 Core Functional Description

All components realize full interlocked operation for hazardous oilfield BOP handling equipment hydraulic power output, explosion-proof electric logic control, hydraulic pressure self-regulation, loop impurity filtration, fluid state monitoring and safe load traction. ZKYZ-630II electric control box assembly integrates low-voltage control components to realize soft motor startup, circuit overload protection and linkage signal transmission; explosion-proof motor and variable gear pump provide stable hydraulic power for J2K-160 cycloid system; combined overflow relief valve set stabilizes system maximum working pressure; multi-stage oil suction and air filters purify hydraulic medium and cooling air; liquid level thermometer and liquid level relay realize automatic low-oil-level power-off protection; explosion-proof tubular heater prevents hydraulic oil low-temperature viscosity surge in winter operation; FYS0 pulley and dedicated lifting cable undertake heavy-load BOP traction; waterproof plug sockets and aviation connectors guarantee anti-corrosion signal connection in damp drilling yards; pipe brackets and bearing parts reduce pipeline and transmission rotating friction loss.

2.3 Optimized Structural Characteristics

All ZKYZ electrical control parts adopt Ex d IIB T4 integral flameproof enclosure structure; star delta starter comes with built-in current limiting module to cut startup impact current; combined hydraulic valve body adopts forged integral flow passage to avoid high-pressure cracking; filter shell adopts quick-lock buckle structure for element replacement without pipeline draining; FYS0 copper bushing pulley adopts bimetallic wear-resistant composite lining; three-pole waterproof socket owns double-layer silicone sealing structure; all hydraulic adapters and tee joints adopt precision cold-forged thread for zero leakage assembly. On-site practical design: unified wiring terminal datum for ZKYZ electric cabinet parts, laser-etched pressure grade mark on valve surface, reserved detachable mounting base for pipe bracket assembly.

2.4 Adaptable Oilfield Working Conditions

Adapt ambient operating temperature ranging from -35℃ to 85℃; fit Zone1 hydrocarbon mixed explosive atmosphere, saline-alkali mud corrosion, 24-hour heavy-load reciprocating BOP traction working environments; stable operation under 31MPa maximum hydraulic system pressure and 250kN rated BOP lifting load; compatible with ISO VG68 anti-explosion hydraulic oil; applicable for inland explosive-class drilling and BOP maintenance operation zones.

2.5 Engineer Verified Maintenance Rules & On-site Avoidance Tips

Replace oil suction and return filter elements every 340 continuous BOP hoisting hours; calibrate liquid level relay trigger threshold every 730 cyclic operation hours; inspect explosion-proof junction sealing gasket before daily equipment startup; critical avoidance tip: do not mix install 10A and 32A fuse cores arbitrarily, which will mismatch circuit load rating and cause explosion-proof cabinet internal arcing risk.

We supply the following spare parts:

ZKYZ-630II-W2600 Star Delta Starter

ZKYZ-630II-W4200 fuse core 10A

ZKYZ630II-W1200 Oil Suction Filter

ZKYZ630II-W0400 explosion-proof motor

Small relay HH54P

Air filter C-M60X2

604-1114 J2K-160 Cycloid Motor Hydraulic System

ZKYZ-630II.13 Connector

ZHYZ1000-01 Connector

Liquid level thermometer YWZ-250T

ZKYZ-630I.90.00 electric control box assy

BYT201-25.4A.00 Oil pump motor assembly

ZKYZ-630II.09.01B valve block

AC Contactor GSC1-1810DM7

ZKYZ-630II-W3400 DC 24V power supply

Gear Pump CBF-25P

DB10-2-30/315 Overflow Valve HydraulicSystem

Auxiliary Contact Group F3-22D

ZKYZ-630II-W3600 Three-pole waterproof plug socket

ZKYZ630II-W1500 Liquid level gauge

Relief valve DB20-1-50/315

FYS0-01.04.02 Cupper Bushing Pulley

ZKYZ630II-W1600 liquid level relay

BYT212-400.2-00 Cooler assembly

ZKYZ630II-W0300 explosion proof motor

GB301-84 Bearing 8205 Pipe hanqer

ZKYZ-630II-W1201 Oil suction filter element

ZKYZ-630II-W2700 AC Contactor

ZKYZ630II-W1800 Explosion-proof tubular heater

Variable pump 80SCY14-1B

ZKYZ-630II-W1301 oil return filter element

Thermal relay JRS4-65361D/Z

ZKYZ630II-W0600 shaft coupling

Three-pole circuit breaker GSM1-225M/3300

ZKYZ630II-W180 Tubal beater

FD12FA12/B30 Compensation Valve Hydraulic System

BYT317-15 adapter

ZKYZ630II-W1400 C Type air filter

Oil suction filter TF-400X180F-Y

ZKYZ-630II-W3000 Thermal relay 1.6-2.5A

Explosion-proof thermal resistance WZP-24SA T4

ZKYZ-630II-W2800 AC Contactor

GB276-82 Bearing 306 Gear Reducer

Liquid level relay gauge YKJD24-300

ZKYZ-630II.14A Tee joint body

ZKYZ-630II.17.00 pipebracket rssy

ZKYZ-630II-W4100 fuse core 32A

ZKYZ-630II.14A 3-way adapter

RVPl 0-10 Check Valve HydraulicSystem

FYS0-09.02 Lift Cable φ28 BOP Handling System

 

3. Verified On-site Oilfield Maintenance Cases (4 Cases)

Case 1

Location: Ordos Explosive Drilling BOP Yard; Matched Device: ZKYZ-630II Electric Control Cabinet; Working Load: 240kN BOP cyclic lifting load; Fault Data: Direct startup motor current surge burned contactor contacts; Repair Scheme: Install ZKYZ-630II-W2600 star delta starter + JRS4-65361D/Z thermal relay; Post-repair Index: Motor startup current limited below 32A, zero contact ablation for long-cycle operation; Client Feedback: Eliminated cabinet arcing hidden danger, compliant with site explosion-proof operation code.

Case 2

Location: Yumen Saline-Alkali BOP Maintenance Station; Matched Device: 604-1114 J2K-160 Cycloid Hydraulic System; Working Load: 29MPa fluctuating hydraulic pressure; Fault Data: Single relief valve failure caused system overpressure alarm; Repair Scheme: Equip DB10-2-30/315 overflow valve + DB20-1-50/315 relief valve combined assembly; Post-repair Index: System peak pressure locked below 30MPa, stable pressure unloading realized; Client Feedback: Protected gear pump and valve block from high-pressure impact damage.

Case 3

Location: Tarim Winter Low-temperature BOP Operation Base; Matched Device: BYT201-25.4A.00 Oil Pump Power Unit; Working Load: 230kN hydraulic output thrust; Fault Data: Low-temperature oil viscosity rise caused pump oil suction deficiency; Repair Scheme: Install ZKYZ630II-W1800 explosion-proof heater + TF-400X180F-Y oil suction filter; Post-repair Index: Hydraulic oil working viscosity kept within standard range, pump oil supply stable; Client Feedback: Solved winter oil starvation pump cavitation fault in desert low temperature.

Case 4

Location: Qingdao Onshore BOP Hoisting Workshop; Matched Device: FYS0 BOP Traction Mechanism; Working Load: 220kN cable traction load; Fault Data: Worn pulley bushing caused φ28 lifting cable offset abrasion; Repair Scheme: Replace FYS0-01.04.02 copper bushing pulley + original FYS0-09.02 lift cable; Post-repair Index: Cable lateral offset controlled below 0.13mm, uniform bearing stress achieved; Client Feedback: Reduced traction cable replacement frequency, lowered onsite hoisting safety risk.

4. User Intent Targeted FAQ Table

Serial Number

Common Procurement & On-site Operation Question

Professional Field Engineer Practical Answer

1

Can ZKYZ-630II-W0300 and W0400 explosion-proof motors interchange installation?

They differ in rated power and flange size, only match dedicated pump assembly, cannot cross assemble on hydraulic power unit.

2

What is the matched working pressure of DB10 and DB20 hydraulic valve sets?

DB10 acts as primary overflow protection, DB20 serves secondary pressure relief, combined use limits system pressure within 31MPa.

3

Is HH54P small relay exclusive for ZKYZ-630II control loop?

It matches cabinet internal 24V signal protocol, fixed pin definition, direct plug installation without circuit modification.

4

Which components belong to priority stocked hazardous site wearing parts?

Priority stock filter elements, fuse cores, contactors, explosion-proof sealing gaskets and hydraulic check valves for emergency replacement.

5

Does FYS0 φ28 lift cable apply for all BOP handling models?

It is customized for FYS0 series pulley groove size, not applicable for other caliber traction pulley assemblies.

5. Procurement Guidance & Closing Paragraph

This full set of ZKYZ-630II explosion-proof electric control assemblies, BY series hydraulic power parts, DB combined hydraulic valve units, FYS0 BOP traction components and oilfield explosion-proof filtration connecting fittings comply with original ZKYZ control cabinet and FYS0 BOP handling equipment OEM tolerance standards, attached with ATEX explosion-proof inspection reports, hydraulic pressure fatigue test certificates and complete electric-hydraulic assembly drawings for buyer technical audit, hazardous area warehouse filing and equipment overhaul technical reference. All finished components complete hydrocarbon gas aging test, flameproof tightness test and electric hydraulic linkage matching test before outbound delivery, complying with global Zone1 oilfield BOP equipment spare part supply specifications. We support single-spec bulk procurement, full BOP hydraulic-electric overhaul combined kit matching and special-thread hydraulic adapter customized processing services. Professional explosion-proof hydraulic-electrical engineering team provides host model matching confirmation, onsite hazardous zone fault diagnosis and customized cyclic maintenance scheme guidance for procurement managers and certified field maintenance technicians. Reach out to confirm explosion-proof working condition matching, combined component selection and full-cycle professional technical support for your BOP handling equipment spare part reserve and system renovation overhaul projects.

 


Prosperity Petroleum Equipment

Quick Inquiry