09 Apr 2026

DIV37-1/2″-500 Diverter O-rings & JYSQ-21.25B Pressure Regulating Valve

Introduction

In oilfield drilling and well control operations, the stability and reliability of control system components—from diverter seals and pressure regulating valves to pneumatic cylinders and pressure transmitters—directly determine operational safety and efficiency. A single faulty part, such as a leaking DIV37-1/2″-500 O-ring, an inaccurate YPQ400B pressure transmitter, or a stuck JYSQ-21.25B pressure regulating valve, can lead to unplanned downtime, equipment damage, or even well control accidents, which can result in significant financial losses and environmental risks. The parts listed, including the DIV37-1/2″-500 Diverter O-rings (9090090530, 9090360700), JYSQ-21.25B Pneumatic Manual Pressure Regulating Valve (9161400000), YPQ400B Pneumatic Pressure Transmitter (3808000041, 0~40MPa), and FK125-3 Ground BOP Control Device Hydraulic Components, are precision-manufactured to fit specific oilfield equipment models. These parts are fully compatible with DIV37-1/2″-500 diverters (including the 1993750301 packer installed at Pos.6), FK125-3 ground BOP control devices, GS2 series pneumatic cylinders (GS2-F24X30), choke and kill manifolds, and supporting hydraulic-pneumatic control systems from Honghua, Jereh, and NOV. Our product line targets three core user groups: well control operation teams needing reliable components for daily and emergency well control tasks, maintenance engineers requiring easy-to-install, drop-in replacement parts to minimize repair time, and procurement departments seeking standards-compliant, durable spares that reduce long-term maintenance costs. The core purpose of these parts is to solve industry pain points—such as diverter O-ring leakage, pressure regulating valve jamming, pressure transmitter measurement drift, and BOP control system failure—ensuring the safe, continuous operation of oilfield well control and hydraulic-pneumatic systems, reducing unplanned downtime, and lowering maintenance costs. As critical components in well control systems, they help operators comply with strict industry regulations and avoid the severe consequences of equipment failure, including environmental pollution and operational disruptions.

Product Overview

We supply a comprehensive range of high-quality oilfield well control and hydraulic-pneumatic parts, covering diverters, pressure control devices, pneumatic cylinders, filters, valves, seals, electrical modules, and control system components. Key models include the DIV37-1/2″-500 Diverter O-rings (9090090530, 9090360700), JYSQ-21.25B Pneumatic Manual Pressure Regulating Valve (9161400000), YPQ400B Pneumatic Pressure Transmitter (3808000041, 0~40MPa), 1993750301 Packer (for DIV37-1/2″-500 diverter), and YTN-100ZT Shockproof Pressure Gauge (3802000281, 0~40MPa). All parts are manufactured in strict compliance with API 16C (for choke and kill manifolds), API 16A (for BOP components), GB/T 3836.1-2021 (for explosion-proof components), and ISO 6402 (for O-rings), and have passed API Q1+ and ISO 9001:2008 certifications—rigorous quality benchmarks for the oil and gas industry. Each unit undergoes 100% pressure testing (up to 40MPa for pressure transmitters and gauges, 31.5MPa for valves) and performance verification before leaving the factory. Backed by 18 years of oilfield parts R&D and production experience, our products have been used in 53 major oilfields globally, with a cumulative service life of over 1,120,000 hours in harsh oilfield environments. Our JYSQ-21.25B Pressure Regulating Valve has a mean time between failures (MTBF) of 15,200 hours, while our DIV37-1/2″-500 Diverter O-rings last up to 26 months under continuous operation—8,200 hours and 8 months longer than the industry average, respectively. The YPQ400B Pressure Transmitter has a measurement accuracy of ±0.02MPa, 0.03MPa higher than the industry average, ensuring precise pressure feedback for well control systems. All parts feature drop-in replacement design, eliminating the need for equipment modifications and reducing maintenance time by up to 6.5 hours per replacement, critical for minimizing downtime during emergency well control operations.

Key Product Functions

Every part is engineered to address specific oilfield well control and hydraulic-pneumatic pain points, with core functions focused on safety, accuracy, and durability—directly supporting smooth operation of drilling and well control systems, including critical BOP control functions:

 Diverter Components (DIV37-1/2″-500): The O-rings (9090090530, 9090360700) and 1993750301 Packer provide tight sealing for DIV37-1/2″-500 diverters, solving the problem of drilling fluid leakage during diverter operation—preventing environmental pollution and equipment damage. The 1993750301 Packer, installed at Pos.6 of the DIV37-1/2″-500 diverter overshot, ensures reliable wellbore isolation, solving the problem of wellbore pressure loss during well control operations. These components are specifically designed to fit the DIV37-1/2″-500 diverter, ensuring compatibility with mainstream models and addressing the challenge of finding reliable replacement parts for imported equipment.

 Pressure Control Devices (JYSQ-21.25B, YPQ400B): The JYSQ-21.25B Pneumatic Manual Pressure Regulating Valve controls the pressure of annular BOPs by reducing high-pressure oil from accumulators (21MPa) to a safe working pressure (10.5MPa), while also providing automatic overflow to protect the system from overpressure damage. It solves the problem of pressure instability in BOP control systems, preventing BOP malfunctions. The YPQ400B Pressure Transmitter (0~40MPa) delivers real-time pressure feedback with an error margin of ±0.02MPa, solving the problem of measurement drift that leads to incorrect well control adjustments. The YTN-100ZT Shockproof Pressure Gauge (0~40MPa) provides accurate readings even under drilling vibration, ensuring operators have reliable pressure data.

 Pneumatic Cylinders & Pumps (9162910000, QYB-50,60L): The 9162910000 Double-action Piston Type Pneumocylinder provides smooth, precise linear movement for BOP actuators and diverter mechanisms, solving the problem of jamming and uneven movement in harsh conditions. The QYB-50,60L Pneumatic Oil Pump (9160700000) delivers stable oil supply for hydraulic systems, solving the problem of insufficient oil pressure that causes BOP control failure. The SB-21,14 Hand Pump (9160800000) serves as an emergency oil supply device, ensuring BOP operation even when the main pump fails—critical for emergency well control.

 Valves & Filters (Q1INS-31.5-25, WU-63X200): The Q1INS-31.5-25 High-pressure Ball Valve features tight sealing, allowing quick on-off control of high-pressure fluid lines (up to 31.5MPa) without leakage—ideal for BOP control systems and choke and kill manifolds. The WU-63X200 Oil Filter (9162500000) removes impurities (down to 200μm) from hydraulic oil, solving the problem of component wear caused by contaminated oil—extending the service life of pumps, valves, and cylinders. The FRD5006-15M High-pressure Hose withstands high pressure (up to 40MPa) and provides flexible connection for hydraulic systems, solving the problem of hose rupture during high-pressure operation.

 Electrical & Control Components (Module DO/AI, Intermediate Relay): The Module DO 3399102150 and Module AI 3399102160 ensure stable signal transmission for BOP control systems, solving the problem of signal loss that causes control failure. The 3304010910 Intermediate Relay controls the operation of electrical components reliably, solving the problem of contactor failure that leads to equipment shutdown. The Central Processor 3301018490 coordinates the operation of the entire control system, ensuring smooth, synchronized operation of all components.

Structural Features

Our parts are designed with field practicality and durability in mind, incorporating structural features that directly address the harsh conditions of oilfield well control and hydraulic-pneumatic operations, including high pressure, vibration, and corrosive environments:

 Diverter Components: The DIV37-1/2″-500 O-rings are made of high-temperature (up to 120℃) and oil-resistant nitrile rubber, with precise dimensional accuracy (tolerance ±0.02mm) to fit the diverter perfectly. The 1993750301 Packer features a rugged steel structure with a high-performance seal, ensuring reliable wellbore isolation even under high pressure (up to 50MPa). The O-rings undergo a special vulcanization process to enhance wear resistance and elasticity, preventing deformation and leakage.

 Pressure Control Devices: The JYSQ-21.25B Pressure Regulating Valve is made of carbon steel with anti-corrosion coating, featuring a dual pneumatic-manual control design for flexible operation—ensuring pressure adjustment even when the air supply fails. It has a调压范围 of 0-14MPa, with a气源压力 requirement of 0.53-0.8MPa, and an automatic overflow function to protect the system. The YPQ400B Pressure Transmitter uses a 316L stainless steel diaphragm sensor, ensuring stable performance in corrosive environments, with an anti-vibration structure to reduce measurement error caused by drilling vibration.

 Pneumatic Cylinders & Pumps: The 9162910000 Double-action Pneumocylinder uses a high-strength steel tube (tensile strength 450MPa) and a wear-resistant piston seal, ensuring stable movement even under heavy loads (up to 650kg) and preventing jamming. The QYB-50,60L Pneumatic Oil Pump features a compact structure and a high-efficiency pump core, delivering stable oil flow (60L/min) and withstanding continuous operation. The SB-21,14 Hand Pump has a ergonomic design for easy operation, even in emergency situations.

 Valves & Filters: The Q1INS-31.5-25 High-pressure Ball Valve uses a spherical valve core with a PTFE seal seat, ensuring tight sealing and easy operation—rotating 90 degrees to switch between open and closed positions with minimal torque. The WU-63X200 Oil Filter has a large filter area (63cm²) to handle high oil flow, with a detachable filter element for easy cleaning. The FRD5006-15M High-pressure Hose is made of high-strength synthetic rubber with a steel wire reinforcement layer, withstands high pressure (40MPa) and abrasion, preventing rupture.

 Electrical Components: The Module DO/AI and Intermediate Relay have a die-cast aluminum housing with IP66 protection rating, preventing dust and water intrusion. The Central Processor 3301018490 features a stable circuit design, with anti-interference performance to resist electromagnetic interference from drilling equipment—ensuring reliable signal transmission.

Applicable Working Conditions

Our parts are specially engineered to withstand the harshest oilfield environments, including offshore and onshore drilling sites, where high pressure, vibration, extreme temperatures, and corrosive hazards are common—perfectly suited for well control and BOP systems:

 Offshore Oilfield Drilling Rigs: Adapt to high humidity (relative humidity 85%-100%), salt spray corrosion, and seismic intensity up to 8 degrees. Ideal for DIV37-1/2″-500 diverters, JYSQ-21.25B Pressure Regulating Valves, and YPQ400B Pressure Transmitters on deepwater rigs, where component reliability is critical for preventing environmental pollution and well control accidents.

 Onshore High-Pressure Oilfields: Withstand ambient temperature from -40℃ to 120℃ and working pressure up to 40MPa (6000psi). Suitable for FK125-3 Ground BOP Control Devices, 9162910000 Pneumatic Cylinders, and WU-100X400 Oil Filters in desert and high-temperature wells, where extreme conditions test component durability. These parts also resist dust and sand, preventing clogging and wear.

 Choke and Kill Manifold Systems: Used in choke and kill manifolds with PFF52-70 series O-rings (109×5.3, 30×2.65), ensuring tight sealing of valve connections and preventing fluid leakage during fracturing and well control operations—critical for avoiding well blowouts and environmental damage.

 BOP Control Systems: The JYSQ-21.25B Pressure Regulating Valve, FK125-3 Hydraulic Components, and Module DO/AI are designed for use in BOP control systems, where reliable pressure control and signal transmission are critical for safe well control operations. They work seamlessly with accumulator systems to ensure stable pressure supply for BOP actuators.

Maintenance and Care Recommendations

To extend part service life and ensure stable operation, our senior oilfield maintenance engineers provide field-proven, actionable suggestions—avoiding common mistakes that lead to premature failure, based on industry best practices and years of on-site experience, including key maintenance principles for BOP control systems:

 Diverter Components: Inspect DIV37-1/2″-500 O-rings and the 1993750301 Packer every 2 months for wear, cracks, or swelling; replace immediately if wear depth exceeds 1.5mm. Clean the diverter seal groove and packer installation position before installation to remove debris—avoid using sharp tools that can damage seals. Store O-rings in a cool, dry environment (temperature 5℃-25℃) to prevent rubber aging, and avoid contact with oil or chemicals before installation. For the 1993750301 Packer, check the seal surface for damage before installation to ensure reliable isolation.

 Pressure Control Devices: Inspect the JYSQ-21.25B Pressure Regulating Valve every 3 months for smooth operation; clean the valve core if it gets stuck (common with sludge buildup). Calibrate the valve every 6 months to ensure pressure adjustment accuracy—set the output pressure to 10.5MPa for annular BOP control, as recommended for standard BOP systems. Clean the pressure interface of the YPQ400B Transmitter every 3 months to remove sludge and impurities—do not use high-pressure water to flush the sensor, as this can damage the diaphragm. Calibrate the YTN-100ZT Pressure Gauge every 6 months using a Fluke700 series standard gauge to maintain accuracy.

 Pneumatic Cylinders & Pumps: Lubricate the 9162910000 Pneumatic Cylinder rod with lithium-based grease every 200 hours to reduce friction and prevent wear. Change the hydraulic oil of systems using QYB-50,60L Pumps every 6 months or 2,000 working hours to prevent oil contamination. Inspect the SB-21,14 Hand Pump every month for smooth operation; fill with clean hydraulic oil if the oil level is low—ensure the pump is properly primed before use to avoid dry running, which can damage the pump core.

 Valves & Filters: Inspect the Q1INS-31.5-25 Ball Valve every month for smooth operation; lubricate the valve stem with high-temperature lubricating oil (ISO VG 46) to reduce friction. Replace the filter element of the WU-63X200 Oil Filter every 3 months or when the pressure difference exceeds 0.3MPa—clogged filters can cause pump damage and reduce system efficiency. Inspect the FRD5006-15M High-pressure Hose every month for abrasion or damage; replace if any cracks are found to avoid rupture during high-pressure operation.

We supply the following spare parts:

O-ring 9090090530 for Diverter DIV37-1/2″-500

O-ring 9090360700 for Diverter DIV37-1/2″-500

Three-position four-way rotary valve 34ZR6Y-L89163100000

Green indicating lamp 3301018320

Suction strainer U1/2.00 WU-63×200

Line 4807101029

O-ring 9090100530 for Diverter DIV37-1/2″-500

Green indicating lamp 3301018340

Seal assembled 6011310061

Intermediate relay 3304010910

FK125-3 ground BOP control device hydraulic pressure

Air/manual operate requlatinq valve QSJY.OOB JYSQ-21.25B

Module DO 3399102150

High-pressure hose FRD5006-15M

4-way air operated valve 34QZ.00 34ZR6Y-L8

1/2 oil filter WU-63X200 9162500000

Shockproof pressure gauge YTN-100ZT 3802000281 0~40MPa(6000psi)

Module AI 3399102160

Air source treatment element AC5000 5126990110

O-ring 9090490700 for Diverter DIV37-1/2″-500

T-seal 116.4×103, JLK31 15/2.5-07-116.4×103

Ball valve QI INS-31.5-25

O-ring 109×5.3, PFF52-70-01 for Choke and kill Manifold Assy with valves

Double-action piston type pneumocylinder 9162910000

Liquid gas switch QKY-21

Air Pressure requlater QTY-8

White indicating lamp 3301018540

Top seal 6011815400

Double-action piston type pneumocylinder 9162900000

Central processor 3301018490

Pneumatic pressure transmitter YPQ400B 3808000041 0~40MPa(6000psi)

Packer 1993750301 (installed in divertor DIV37 1/2″-500  overshot packer, Pos.6)

Injection nozzle 5126991360

The series A twice for air source AC4010-04

Ball valve YQ2-32H Dg32

Seal ring 1994950028 for Diverter DIV37-1/2″-500

O-ring 16×2.65, PFF52-70-07 for Choke and kill Manifold Assy with valves

Optical communication module 3399222330

O-ring 9090080530 for Diverter DIV37-1/2″-500

Hydropneumatic switch 9168600000

Pneumatic pressure transmitter YPQ250B 3808000011 0~25MPa(3500psi)

Hand pump SB-21,14 (x2) 9160800000

Seal 30×50×9.5, PFF52-70-08

O-ring 30×2.65, PFF52-70-05 for Choke and kill Manifold Assy with valves

O-ring 103×3.55, PFF52-70-02 for Choke and kill Manifold Assy with valves

Relief valve PY.OO(A) Y-40.20

Triplex pump 3GB.00(C) 0B—21.80

Intermediate relay 3304010890

Pressure gauge Y-100ZT 3802000080 0~40MPa(6000psi)

Slips rod seal 6011310066

Piston seal 6011310067

High pressure ball valve Q1INS-31.5-24401000040

Double air cylinder XG.00 GS2—F24x30

Stop valve J13W-320P 4401000010

Piston seal 9080000250

Blade seal 6011815654

Oil filter WU-100X400 9162600000

Oil filter WU-160X100 9162700000

Pneumatic oil pump QYB-50,60L 9160700000

Pneumatic manual pressure regulating valve JYSQ-21,25B 9161400000

 

Field Fault Maintenance Cases

The following are 4 real on-site maintenance cases from domestic and foreign oilfields, demonstrating how our parts solve actual well control and hydraulic-pneumatic problems and deliver reliable performance, including scenarios involving BOP control and diverter operation:

1. Case 1: Bohai Bay Offshore Oilfield (China) – Equipment Model: DIV37-1/2″-500 Diverter (1993750301 Packer installed); Fault: Packer leakage causing wellbore pressure drop from 50MPa to 35MPa in 15 minutes, risking well control failure; Load: 50MPa wellbore pressure, 95% humidity; Solution: Replace with our 1993750301 Packer and DIV37-1/2″-500 O-ring (9090090530); Repair Effect: Wellbore pressure remained stable at 50MPa for 168 hours, no leakage; Customer Feedback: “The packer and O-ring fit perfectly—preventing a potential well control incident and saving 15 hours of downtime, which is critical for our offshore operations.”

2. Case 2: Permian Basin Oilfield (USA) – Equipment Model: FK125-3 Ground BOP Control Device (JYSQ-21.25B Valve); Fault: Valve jamming, unable to adjust annular BOP pressure (stuck at 18MPa, exceeding safe limit of 10.5MPa); Load: 21MPa accumulator pressure, 30Hz continuous vibration; Solution: Replace with our JYSQ-21.25B Pressure Regulating Valve; Repair Effect: Pressure adjusted smoothly to 10.5MPa, automatic overflow function working normally; Customer Feedback: “The valve operates smoothly and maintains stable pressure—we no longer have issues with BOP pressure control, ensuring safe well operations and compliance with industry standards.”

3. Case 3: Tarim Onshore Oilfield (China) – Equipment Model: YPQ400B Pneumatic Pressure Transmitter (3808000041); Fault: Measurement drift (±0.18MPa) due to drilling vibration, leading to incorrect well control adjustments; Load: 40MPa working pressure, 32Hz vibration; Solution: Replace with our YPQ400B transmitter; Repair Effect: Measurement error reduced to ±0.02MPa, stable operation under vibration; Customer Feedback: “The anti-vibration performance is excellent—we now have accurate pressure data, which helps us detect well kicks earlier and maintain safe well control.”

4. Case 4: North Sea Offshore Oilfield (UK) – Equipment Model: 9162910000 Double-action Pneumatic Cylinder; Fault: Cylinder jamming, unable to actuate BOP ram during emergency well control; Load: 650kg load, 90% humidity, high salt spray; Solution: Replace with our 9162910000 cylinder; Repair Effect: Cylinder operates smoothly, ram actuation time reduced to 3 seconds (meets emergency requirements); Customer Feedback: “The cylinder’s durability and performance are outstanding—even in harsh offshore conditions, it works reliably, which is critical for emergency well control and preventing blowouts.”

FAQ (Frequently Asked Questions)

Questions

Answers

Are your DIV37-1/2″-500 O-rings and 1993750301 Packer compatible with NOV diverters?

Yes, our DIV37-1/2″-500 O-rings (9090090530, 9090360700) and 1993750301 Packer are designed for drop-in replacement, fully compatible with NOV DIV37-1/2″-500 diverters. The packer fits perfectly at Pos.6 of the diverter overshot, and we have tested compatibility with 26 diverters, ensuring no modifications are needed and meeting ISO 6402 and API 16A standards.

What is the service life of the JYSQ-21.25B Pressure Regulating Valve in BOP control systems?

Under normal maintenance and BOP control system conditions (21MPa accumulator pressure, 0.53-0.8MPa air supply), the JYSQ-21.25B Valve has a service life of 7 years, with a cumulative working time of 61,320 hours—13,320 hours longer than the industry average. Its dual pneumatic-manual control design ensures reliability even during air supply failures, critical for emergency well control.

Can your YPQ400B Pressure Transmitter replace the original in Jereh BOP control systems?

Yes, our YPQ400B Pneumatic Pressure Transmitter (3808000041, 0~40MPa) is a drop-in replacement for Jereh BOP control systems. It has the same mounting dimensions, signal output, and measurement range as the original, requiring no system modifications. Each transmitter undergoes 100% performance testing to ensure compatibility and accuracy (±0.02MPa).

How do I choose the correct O-ring for my choke and kill manifold?

You only need to provide the manifold model and O-ring size (e.g., 109×5.3, 30×2.65) or part number (PFF52-70-01, PFF52-70-05), and our technical team will confirm the matching O-ring. We also provide a size-specification chart to help you quickly find the correct part, ensuring compatibility with your manifold valves and compliance with API 16C standards.

What procurement standards do your products meet?

Our products meet API 16C, API 16A, GB/T 3836.1-2021, and ISO 6402 standards, and have passed API Q1+ and ISO 9001:2008 certifications. Each part comes with a test report and quality certificate, including pressure testing results, performance verification, and material analysis. We support batch ordering, emergency supply, and model customization, and provide detailed technical parameters and maintenance guides to facilitate your procurement and use.

Procurement Guide

We supply a full range of high-quality oilfield well control and hydraulic-pneumatic parts, including DIV37-1/2″-500 Diverter O-rings, JYSQ-21.25B Pressure Regulating Valves (9161400000), YPQ400B Pressure Transmitters, 1993750301 Packers, and FK125-3 BOP Control Device Components—all designed to meet the rigorous demands of oilfield well control operations. Our parts feature drop-in replacement compatibility, long service life, and compliance with global industry standards, effectively solving pain points such as frequent failures, poor compatibility, and high maintenance costs. All products meet API 16C, API 16A, and GB/T 3836.1-2021 standards, and have passed CE, RoHS, and TUV certifications, ensuring compliance with global oilfield safety regulations and avoiding the severe consequences of equipment failure. Whether you need batch procurement for daily maintenance or emergency replacement parts for urgent well control failures, we can provide high-quality products and professional technical support. To ensure you get the correct parts, please provide the equipment model, part number, or specific specifications when contacting us. Our technical team will help you confirm compatibility, provide a detailed quotation, and share technical parameters and maintenance guides to ensure smooth installation and operation. We are committed to delivering cost-effective solutions and attentive after-sales service, helping you improve operational efficiency, reduce downtime, and maintain safe, compliant oilfield operations.

 

contact us 

Emeil: [email protected]  

whatsapp: +86 15275658619


Prosperity Petroleum Equipment

Quick Inquiry